50 Ohm Wireless Transmission Coax, RG-8, 10 AWG Solid Bare Copper Conductor , FEP Insulation, Foil + 90% Tinned Copper Braid Shield, PVDF Jacket, CMP
Specifications
Specifications
Product Overview
| Suitable Applications | Point-to-point and point-to-multipoint wireless antenna communication; Wireless microphones, Two-Way Radios, Amateur (Ham) Radio, Low Power FM, GPS, RFID (Radio Frequency Identification) |
|---|
Construction Details
Conductor
| Size | Stranding | Nom. Diameter | Material |
|---|
| 10 AWG | Solid | 0.108 in | BC - Bare Copper |
Insulation
| Material | Nom. Insulation Diameter | Color Code | Notes |
|---|
| FEP - Fluorinated Ethylene Propylene | 0.292 in (7.42 mm) | Clear | Solid FEP monofilament spiral around conductor. Solid FEP tube over monofilament |
Outer Shield
| Layer | Outer Shield Type | Material | Material Trade Name | Coverage |
|---|
| 1 | Tape | Tri-Laminate (Alum+Poly+Alum) | Duobond® II | 100% |
| 2 | Braid | Tinned Copper (TC) | | 90% |
Outer Jacket
| Material | Nom. Diameter |
|---|
| PVDF - Polyvinylidene Fluoride | 0.360 in (9.14 mm) |
| Overall Cable Diameter (Nominal) | 0.360 in (9.14 mm) |
|---|
Electrical Characteristics
Attenuation
| Frequency | Nom. Attenuation |
|---|
| 1 MHz | 0.1 dB/100ft |
| 10 MHz | 0.4 dB/100ft |
| 50 MHz | 1.0 dB/100ft |
| 100 MHz | 1.6 dB/100ft |
| 200 MHz | 2.3 dB/100ft |
| 400 MHz | 3.4 dB/100ft |
| 700 MHz | 5.0 dB/100ft |
| 900 MHz | 6.0 dB/100ft |
| 1000 MHz | 6.9 dB/100ft |
Electricals
| Nom. Conductor DCR | Nom. Outer Shield DCR | Nom. Capacitance
Cond-to-Shield | Nom. Characteristic Impedance | Nom. Velocity of Prop. |
|---|
| 0.9 Ohm/1000ft | 3.3 Ohm/1000ft (11 Ohm/km) | 25 pF/ft (82 pF/m) | 50 Ohm | 83% |
Voltage
| UL Voltage Rating |
|---|
| 300 V (CMP) |
Mechanical Characteristics
Temperature
| UL Temperature | Operating |
|---|
| 150°C | -15°C to +150°C |
Bend Radius
| Installation Min. |
|---|
| 3.6 in (91 mm) |
| Max. Pull Tension | 174 lbs (78.9 kg) |
|---|
| Bulk Cable Weight | 119 lbs/1000ft |
|---|
Standards and Compliance
| Environmental Suitability | Indoor - Plenum, Indoor, Outdoor, UV Resistance, Aerial - When supported by messenger wire |
|---|
| Sustainability | CA Prop 65 |
|---|
| Flammability / Reaction to Fire | NFPA 262 |
|---|
| CPR Compliance | CPR Euroclass: Eca |
|---|
| NEC / UL Compliance | CMP |
|---|
| CEC / C(UL) Compliance | CMP |
|---|
| European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
|---|
| UK Regulation Compliance | UKCA Mark |
|---|
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
|---|
| Non-Plenum Number | 9913 |
|---|
Product Notes
| Notes | Recommend use of 7733A for applications above 1 GHz. |
|---|
History
| Update and Revision | Revision Number: 0.492 Revision Date: 04-13-2023 |
|---|
Documentation
Product Bulletins
Solution Guides
Tools
White Papers
Training
Compliance Documentation
Data Sheets