Description

50 Ohm Wireless Transmission Coax, RG-8, 10 AWG Solid Bare Copper Conductor , FEP Insulation, Foil + 90% Tinned Copper Braid Shield, PVDF Jacket, CMP

Specifications

Specifications

Product Overview

Suitable ApplicationsPoint-to-point and point-to-multipoint wireless antenna communication; Wireless microphones, Two-Way Radios, Amateur (Ham) Radio, Low Power FM, GPS, RFID (Radio Frequency Identification)

Construction Details

RG Type8

Conductor

SizeStrandingNom. DiameterMaterial
10 AWGSolid0.108 inBC - Bare Copper

Insulation

MaterialNom. Insulation DiameterColor CodeNotes
FEP - Fluorinated Ethylene Propylene0.292 in (7.42 mm)ClearSolid FEP monofilament spiral around conductor. Solid FEP tube over monofilament

Outer Shield

LayerOuter Shield TypeMaterialMaterial Trade NameCoverage
1TapeTri-Laminate (Alum+Poly+Alum)Duobond® II100%
2BraidTinned Copper (TC)90%

Outer Jacket

MaterialNom. Diameter
PVDF - Polyvinylidene Fluoride0.360 in (9.14 mm)
Overall Cable Diameter (Nominal)0.360 in (9.14 mm)

Electrical Characteristics

Attenuation

FrequencyNom. Attenuation
1 MHz0.1 dB/100ft
10 MHz0.4 dB/100ft
50 MHz1.0 dB/100ft
100 MHz1.6 dB/100ft
200 MHz2.3 dB/100ft
400 MHz3.4 dB/100ft
700 MHz5.0 dB/100ft
900 MHz6.0 dB/100ft
1000 MHz6.9 dB/100ft

Electricals

Nom. Conductor DCRNom. Outer Shield DCRNom. Capacitance Cond-to-ShieldNom. Characteristic ImpedanceNom. Velocity of Prop.
0.9 Ohm/1000ft3.3 Ohm/1000ft (11 Ohm/km)25 pF/ft (82 pF/m)50 Ohm83%

Voltage

UL Voltage Rating
300 V (CMP)

Mechanical Characteristics

Temperature

UL TemperatureOperating
150°C-15°C to +150°C

Bend Radius

Installation Min.
3.6 in (91 mm)
Max. Pull Tension174 lbs (78.9 kg)
Bulk Cable Weight119 lbs/1000ft

Standards and Compliance

Environmental SuitabilityIndoor - Plenum, Indoor, Outdoor, UV Resistance, Aerial - When supported by messenger wire
SustainabilityCA Prop 65
Flammability / Reaction to FireNFPA 262
CPR ComplianceCPR Euroclass: Eca
NEC / UL ComplianceCMP
CEC / C(UL) ComplianceCMP
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
UK Regulation ComplianceUKCA Mark
APAC ComplianceChina RoHS II (GB/T 26572-2011)
Non-Plenum Number9913

Product Notes

NotesRecommend use of 7733A for applications above 1 GHz.

History

Update and RevisionRevision Number: 0.492 Revision Date: 04-13-2023
View AllClose

Additional Information

Variant_Options:
Item #|Color|Putup Type|Length|UPC
Variant_Options 89913 010500:
89913 010500|Black|Reel|500 ft|612825223870
Variant_Options 89913 0101000:
89913 0101000|Black|Reel|1,000 ft|612825221463
View AllClose