CATV, Series 6, 18 AWG solid .040" bare copper-covered steel conductor(s), gas-injected foam polyethylene insulation, Duobond Plus®; aluminum braid shield (75% coverage), CM PVC jacket.

Specifications

Specifications

Physical Characteristics (Overall)

Conductor

AWGStrandingMaterialNominal DiameterNo. of Coax
18SolidBCCS - Bare Copper Covered Steel0.04 in1
Conductor Count1

Insulation

MaterialNominal Diameter
PE - Polyethylene (Foam)0.18 in
Table NotesGas Injected

Outer Shield

TypeLayerMaterialMaterial Trade NameCoverage [%]
Tape1Tri-Laminate (Alum+Poly+Alum)Duofoil®100%
Braid2Aluminum75%
Tape3Bi-Laminate (Alum+Poly)100%
Table NotesTape has shorting fold and is bonded to jacket

Outer Jacket

MaterialNominal Diameter
PVC - Polyvinyl Chloride0.275 in

Electrical Characteristics

Conductor DCR

Nominal Conductor DCRNominal Outer Shield DCROuter Conductor DCR
28 Ohm/1000ft5.6 Ohm/1000ft5.6 Ohm/1000ft

Capacitance

Nom. Capacitance Conductor to Shield
16.2 pF/ft

Inductance

Nominal Inductance
0.097 µH/ft

Impedance

Nominal Characteristic Impedance
75 Ohm

Return Loss

Frequency [MHz]Min. Structural Return Loss (SRL)
5-1000 MHz20 dB

Delay

Nominal DelayNominal Velocity of Propagation (VP) [%]
1.2 ns/ft83%

High Frequency

Frequency [MHz]Max. Insertion Loss (Attenuation)
5 MHz0.58 dB/100ft
55 MHz1.60 dB/100ft
211 MHz3.05 dB/100ft
270 MHz3.37 dB/100ft
300 MHz3.55 dB/100ft
350 MHz3.85 dB/100ft
400 MHz4.15 dB/100ft
450 MHz4.40 dB/100ft
550 MHz4.90 dB/100ft
750 MHz5.65 dB/100ft
870 MHz6.11 dB/100ft
1000 MHz6.55 dB/100ft

Voltage

UL Voltage Rating
350 V RMS

Temperature Range

Non-UL Temp Rating80°C
Operating Temperature Range-40°C To +80°C

Mechanical Characteristics

Bulk Cable Weight28 lbs/1000ft
Max. Pull Tension138 lbs
Min. Bend Radius/Minor Axis2.75 in

Standards

NEC/(UL) ComplianceCATV, CM
CEC/C(UL) ComplianceCM
RG Type6
Series Type6

Applicable Environmental and Other Programs

Environmental SpaceIndoor (Not Riser or Plenum)
EU Directive 2000/53/EC (ELV)Yes
EU Directive 2003/96/EC (BFR)Yes
EU Directive 2011/65/EU (RoHS 2)Yes
EU Directive 2012/19/EU (WEEE)Yes
EU Directive 2015/863/EU (RoHS 2 amendment)Yes
EU Directive ComplianceEU Directive 2003/11/EC (BFR)
EU CE MarkYes
MII Order #39 (China RoHS)Yes

Suitability

Suitability - IndoorYes

Flammability, LS0H, Toxicity Testing

UL FlammabilityUL1685 UL Loading
UL voltage rating350 V RMS

Plenum/Non-Plenum

Plenum (Y/N)No

History

Update and RevisionRevision Number: 0.374 Revision Date: 04-14-2023
View AllClose

Additional Information