20 AWG solid .031" bare copper conductor, polyethylene insulation, tinned copper/bare copper braid shield (98% coverage), polyethylene jacket.
Specifications
Specifications
Physical Characteristics (Overall)
Conductor
| AWG | Stranding | Material | Nominal Diameter | No. of Coax |
|---|
| 20 | Solid | BC - Bare Copper | 0.031 in | 1 |
Insulation
| Material | Nominal Diameter |
|---|
| PE - Polyethylene | 0.2 in |
Outer Shield
| Type | Layer | Material | Coverage [%] |
|---|
| Braid | 1 | Tinned Copper (TC) | 98% |
| Braid | 2 | Tinned Copper (TC) | 98% |
Outer Jacket
| Material | Nominal Diameter |
|---|
| PE - Polyethylene | 0.305 in |
Electrical Characteristics
Conductor DCR
| Nominal Conductor DCR | Nominal Conductor DCR Conductor Resistance | Nominal Outer Shield DCR | Outer Conductor DCR |
|---|
| 9.9 Ohm/1000ft | 9.9 Ohm/1000ft | 1.1 Ohm/1000ft | 1.1 Ohm/1000ft |
Capacitance
| Nom. Capacitance Conductor to Shield |
|---|
| 20 pF/ft |
Impedance
| Nominal Characteristic Impedance |
|---|
| 75 Ohm |
Return Loss
| Frequency [MHz] | Minimum Return (RL) |
|---|
| 5-216 MHz | 27 dB |
| 217-850 MHz | 23 dB |
High Frequency (Nominal/Typical)
| Frequency [MHz] | Nom. Insertion Loss |
|---|
| 1 MHz | 0.3 dB/100ft |
| 3.6 MHz | 0.5 dB/100ft |
| 10 MHz | 0.8 dB/100ft |
| 71.5 MHz | 2 dB/100ft |
| 135 MHz | 3.5 dB/100ft |
| 270 MHz | 4.3 dB/100ft |
| 360 MHz | 5 dB/100ft |
| 540 MHz | 6.2 dB/100ft |
| 720 MHz | 7.2 dB/100ft |
| 750 MHz | 7.4 dB/100ft |
| 1000 MHz | 9.1 dB/100ft |
Delay
| Nominal Delay | Nominal Velocity of Propagation (VP) [%] |
|---|
| 1.54 ns/ft | 66% |
Voltage
| Non-UL Voltage Rating |
|---|
| 1700 V RMS |
Temperature Range
| Non-UL Temp Rating | 80°C |
|---|
| Operating Temperature Range | -55°C To +80°C |
|---|
Mechanical Characteristics
| Bulk Cable Weight | 68 lbs/1000ft |
|---|
| Max. Pull Tension | 172 lbs |
|---|
| Min. Bend Radius/Minor Axis | 3 in |
|---|
Standards
Applicable Environmental and Other Programs
| Environmental Space | Indoor/Outdoor |
|---|
| EU Directive 2000/53/EC (ELV) | Yes |
|---|
| EU Directive 2003/11/EC (BFR) | Yes |
|---|
| EU Directive 2011/65/EU (RoHS 2) | Yes |
|---|
| EU Directive 2012/19/EU (WEEE) | Yes |
|---|
| EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
|---|
| EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
|---|
| EU CE Mark | No |
|---|
| MII Order #39 (China RoHS) | Yes |
|---|
Suitability
| Suitability - Aerial | No |
|---|
| Suitability - Indoor | Yes |
|---|
| Suitability - Outdoor | No |
|---|
Plenum/Non-Plenum
Related Part Numbers
| Footnote | C - CRATE REEL PUT-UP. |
|---|
Product Notes
| Notes | Dielectric Strength: 8 kV. |
|---|
History
| Update and Revision | Revision Number: 0.323 Revision Date: 11-09-2022 |
|---|
Documentation
Product Bulletins
Catalogs
Tools
Data Sheets