Belden

9182LS - Twinax , 1PR #22 Str TC, PO ins, OS, LSNH Jkt, 300V, SWA

(No reviews yet) Write a Review
SKU:
9182LS
Shipping:
Calculated at Checkout
$0.00

Description

Twinax , 1 Pair AWG 22 Tinned Copper - Stranded, Polyolefin (PO, PE, PP) insulation, Foil(s) or Copper Tape(s) shielding, LSZH / FRNC jacket , 300V, SWA

Specifications

Specifications

Product Overview

Suitable ApplicationsTwinaxial instrumentation and computer cable; For data transmission applications

Physical Characteristics (Overall)

Conductor

AWGStrandingMaterialNo. of Pairs
2219x34TC - Tinned Copper1
Conductor Count2
Total Number of Pairs1

Insulation

MaterialNominal DiameterDiameter +/- Tolerance
PE - Polyethylene (Foam)3.45 mm0.1 mm

Color Chart

NumberColor
Pair 1Black & Yellow

Inner Shield

TypeMaterialMaterial Trade NameThickness of FoilDrainwire MaterialDrainwire AWG
TapeTri-Laminate (Alum+Poly+Alum)Duofoil®9 / 23 / 9 µmTC - Tinned CopperAWG22/19

Inner Jacket

MaterialColorNominal DiameterNominal Wall Thickness
LSZH - Low Smoke Zero Halogen (Flame Retardant)Black8.8 mm0.89 mm

Outer Jacket

MaterialNominal DiameterNominal Wall Thickness
LSZH - Low Smoke Zero Halogen (Flame Retardant)14.25 mm1.4 mm

Construction and Dimensions

Cabling

DescriptionFiller
1 pair and 2 fillers twisted to cable coreFoamed Fibrillated Polypropylene (2x) (White, 2.92 mm)

Armor

Type of ArmorMaterialThickness of Armoring WiresCoverage Percentage
Steel Wire ArmoringGalvanized steel wire1.25 mmMin. 95%

Electrical Characteristics

Conductor DCR

Nominal Conductor DCRNominal Outer Shield DCR
45.9 Ohm/km20.7 Ohm/km

Capacitance

Nom. Capacitance Conductor to ConductorNom. Capacitance Conductor to Shield
28.9 pF/m45.1 pF/m

Inductance

Nominal Inductance
0.96 µH/m

Impedance

Nominal Characteristic Impedance
150 Ohm

High Frequency (Nominal/Typical)

Frequency [MHz]Nom. Insertion Loss
1 MHz1.31 dB/100m
5 MHz2.79 dB/100m
10 MHz3.94 dB/100m
20 MHz5.58 dB/100m
50 MHz8.86 dB/100m
100 MHz14.11 dB/100m
200 MHz20.34 dB/100m
400 MHz28.87 dB/100m

Delay

Nominal DelayNominal Velocity of Propagation (VP) [%]
430 ns/ft78%

Voltage

Voltage Rating [V]
300 V

Temperature Range

Installation Temperature Range-15°C To +80°C
Storage Temperature Range-45°C To +80°C
Operating Temp Range (Flexible Install)-15°C To +80°C
Operating Temp Range (Fixed Install)-45°C To +80°C

Mechanical Characteristics

Oil ResistanceIEC 60811-404
Min. Bend Radius During Installation213.8 mm

Standards

CPR EuroclassFca
CENELEC ComplianceEN 50290-2-20

Applicable Environmental and Other Programs

Environmental SpaceIndoor

Suitability

Suitability - Sunlight ResistanceYes

Flammability, LS0H, Toxicity Testing

IEC FlammabilityIEC 60332-3-24
IEC 60754-1 - Halogen AmountZero
IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity2.5 µS/mm
IEC 60754-2 - Halogen Acid Gas Amount - Min. pH4.3
IEC 61034-2 - Smoke Density Min. Transmittance60%

History

Update and RevisionRevision Number: 0.238 Revision Date: 02-23-2023
View AllClose

Additional Information

Variant_Options:
Item #|Color|Put-Up Type|Length|EAN
Variant_Options 9182LS.001000:
9182LS.001000|Black|Reel|1,000 m|8719605020161
View AllClose