RG-58/U, 20 AWG stranded (19x33) .035" tinned copper conductor, polyethylene insulation, tinned copper braid shield (95% coverage), non-contaminating PVC jacket.
Specifications
Specifications
Physical Characteristics (Overall)
Conductor
AWG | Stranding | Material | Nominal Diameter | No. of Coax |
---|
20 | Stranded | TC - Tinned Copper | 0.035 in | 1 |
Insulation
Material | Nominal Diameter |
---|
PE - Polyethylene | 0.116 in |
Outer Shield
Type | Material | Coverage [%] |
---|
Braid | Tinned Copper (TC) | 95% |
Outer Jacket
Material | Nominal Diameter |
---|
PVC - Polyvinyl Chloride (Non-Contaminating) | 0.195 in |
Electrical Characteristics
Conductor DCR
Nominal Conductor DCR | Nominal Conductor DCR Conductor Resistance | Nominal Outer Shield DCR | Outer Conductor DCR |
---|
10.8 Ohm/1000ft | 10.8 Ohm/1000ft | 4.1 Ohm/1000ft | 4.1 Ohm/1000ft |
Capacitance
Nom. Capacitance Conductor to Shield |
---|
30.8 pF/ft |
Inductance
Nominal Inductance |
---|
0.077 µH/ft |
Impedance
Nominal Characteristic Impedance |
---|
50 Ohm |
High Frequency (Nominal/Typical)
Frequency [MHz] | Nom. Insertion Loss |
---|
1 MHz | 0.4 dB/100ft |
10 MHz | 1.4 dB/100ft |
50 MHz | 3.3 dB/100ft |
100 MHz | 4.9 dB/100ft |
200 MHz | 7.3 dB/100ft |
400 MHz | 11.5 dB/100ft |
700 MHz | 17 dB/100ft |
900 MHz | 20 dB/100ft |
1000 MHz | 21.5 dB/100ft |
Delay
Nominal Delay | Nominal Velocity of Propagation (VP) [%] |
---|
1.54 ns/ft | 66% |
High Frequency
Frequency [MHz] | Max. Insertion Loss (Attenuation) |
---|
50 MHz | 4 dB/100ft |
100 MHz | 6.5 dB/100ft |
400 MHz | 17 dB/100ft |
1000 MHz | 28 dB/100ft |
Power Rating
Frequency [MHz] | Max. Power Rating [W] |
---|
50 MHz | 300 W |
100 MHz | 200 W |
400 MHz | 90 W |
1,000 MHz | 55 W |
Voltage
Non-UL Voltage Rating |
---|
1400 V RMS |
Temperature Range
UL Temp Rating | 85°C |
---|
Operating Temperature Range | -40°C To +85°C |
---|
Mechanical Characteristics
Bulk Cable Weight | 25 lbs/1000ft |
---|
Max. Pull Tension | 42 lbs |
---|
Min. Bend Radius/Minor Axis | 2 in |
---|
Standards
CPR Euroclass | Fca |
---|
RG Type | 58 |
---|
Military Compliance | MIL-DTL-17, M17/28, QPL |
---|
Applicable Environmental and Other Programs
Environmental Space | Indoor (Not Riser or Plenum) |
---|
EU Directive 2000/53/EC (ELV) | Yes |
---|
EU Directive 2003/11/EC (BFR) | Yes |
---|
EU Directive 2011/65/EU (RoHS 2) | Yes |
---|
EU Directive 2012/19/EU (WEEE) | Yes |
---|
EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
---|
EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
---|
EU CE Mark | No |
---|
MII Order #39 (China RoHS) | Yes |
---|
Suitability
Plenum/Non-Plenum
Related Part Numbers
Footnote | C - CRATE REEL PUT-UP. |
---|
History
Update and Revision | Revision Number: 0.344 Revision Date: 11-09-2022 |
---|
Documentation
Product Bulletins
Solution Guides
Tools
White Papers
Training