Audio Coax, Low Noise, RG-59, 22 AWG Solid Bare Copper Covered Steel Conductor, PE Insulation, PVC Conductive Layer, 95% Bare Copper Braid Shield, PVC Jacket
Specifications
Specifications
Product Overview
| Suitable Applications | Low noise microphone, Analog audio, Instrumentation |
|---|
Physical Characteristics (Overall)
Conductor
| AWG | Stranding | Material | Nominal Diameter | No. of Coax |
|---|
| 22 | Solid | BCCS - Bare Copper Covered Steel | 0.025 in | 1 |
Insulation
| Layer | Material | Nominal Diameter |
|---|
| 1 | PE - Polyethylene | 0.146 in |
| 2 | PVC - Polyvinyl Chloride (Conductive) | 0.154 in |
Outer Shield
| Type | Material | Coverage [%] |
|---|
| Braid | Bare Copper (BC) | 95% |
Outer Jacket
| Material | Nominal Diameter |
|---|
| PVC - Polyvinyl Chloride | 0.242 in |
Electrical Characteristics
Conductor DCR
| Nominal Conductor DCR | Nominal Conductor DCR Conductor Resistance | Nominal Outer Shield DCR | Outer Conductor DCR |
|---|
| 54 Ohm/1000ft | 54 Ohm/1000ft | 2.5 Ohm/1000ft | 2.5 Ohm/1000ft |
Capacitance
| Nom. Capacitance Conductor to Shield |
|---|
| 22 pF/ft |
Inductance
| Nominal Inductance |
|---|
| 0.124 µH/ft |
Impedance
| Nominal Characteristic Impedance |
|---|
| 75 Ohm |
Delay
| Nominal Delay | Nominal Velocity of Propagation (VP) [%] |
|---|
| 1.56 ns/ft | 65% |
Voltage
| Voltage Rating [V] |
|---|
| 300 V RMS |
| Electrical Characteristics Notes | NBS Low Noise Test (Modified) MIL-C-17 Paragraph 4.8.14, 5 mV Peak to Peak Max |
|---|
Temperature Range
| Non-UL Temp Rating | 75°C |
|---|
| Operating Temperature Range | -40°C To +75°C |
|---|
Mechanical Characteristics
| Bulk Cable Weight | 36 lbs/1000ft |
|---|
| Max. Pull Tension | 80 lbs |
|---|
| Min. Bend Radius/Minor Axis | 2.4 in |
|---|
Standards
| CPR Euroclass | Eca |
|---|
| RG Type | 59 |
|---|
Applicable Environmental and Other Programs
| Environmental Space | Indoor (Not Riser or Plenum) |
|---|
| EU Directive 2000/53/EC (ELV) | Yes |
|---|
| EU Directive 2003/11/EC (BFR) | Yes |
|---|
| EU Directive 2011/65/EU (RoHS 2) | Yes |
|---|
| EU Directive 2012/19/EU (WEEE) | Yes |
|---|
| EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
|---|
| EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
|---|
| EU CE Mark | Yes |
|---|
| MII Order #39 (China RoHS) | Yes |
|---|
Suitability
| Suitability - Aerial | No |
|---|
| Suitability - Burial | No |
|---|
| Suitability - Hazardous Locations | No |
|---|
| Suitability - Indoor | Yes |
|---|
| Suitability - Outdoor | No |
|---|
| Suitability - Sunlight Resistance | No |
|---|
Plenum/Non-Plenum
Product Notes
| Notes | Not recommended for RF use. Nominal voltage breakdown conductor to shield: 30 kV rms. Nominal voltage breakdown jacket (shield to water): 30 kV rms. |
|---|
History
| Update and Revision | Revision Number: 0.240 Revision Date: 12-19-2022 |
|---|
Documentation
Product Bulletins
Catalogs
Tools