Audio Coax, Low Noise, RG-59, 22 AWG Solid Bare Copper Covered Steel Conductor, PE Insulation, PVC Conductive Layer, 95% Bare Copper Braid Shield, PVC Jacket
Specifications
Specifications
Product Overview
Suitable Applications | Low noise microphone, Analog audio, Instrumentation |
---|
Physical Characteristics (Overall)
Conductor
AWG | Stranding | Material | Nominal Diameter | No. of Coax |
---|
22 | Solid | BCCS - Bare Copper Covered Steel | 0.025 in | 1 |
Insulation
Layer | Material | Nominal Diameter |
---|
1 | PE - Polyethylene | 0.146 in |
2 | PVC - Polyvinyl Chloride (Conductive) | 0.154 in |
Outer Shield
Type | Material | Coverage [%] |
---|
Braid | Bare Copper (BC) | 95% |
Outer Jacket
Material | Nominal Diameter |
---|
PVC - Polyvinyl Chloride | 0.242 in |
Electrical Characteristics
Conductor DCR
Nominal Conductor DCR | Nominal Conductor DCR Conductor Resistance | Nominal Outer Shield DCR | Outer Conductor DCR |
---|
54 Ohm/1000ft | 54 Ohm/1000ft | 2.5 Ohm/1000ft | 2.5 Ohm/1000ft |
Capacitance
Nom. Capacitance Conductor to Shield |
---|
22 pF/ft |
Inductance
Nominal Inductance |
---|
0.124 µH/ft |
Impedance
Nominal Characteristic Impedance |
---|
75 Ohm |
Delay
Nominal Delay | Nominal Velocity of Propagation (VP) [%] |
---|
1.56 ns/ft | 65% |
Voltage
Voltage Rating [V] |
---|
300 V RMS |
Electrical Characteristics Notes | NBS Low Noise Test (Modified) MIL-C-17 Paragraph 4.8.14, 5 mV Peak to Peak Max |
---|
Temperature Range
Non-UL Temp Rating | 75°C |
---|
Operating Temperature Range | -40°C To +75°C |
---|
Mechanical Characteristics
Bulk Cable Weight | 36 lbs/1000ft |
---|
Max. Pull Tension | 80 lbs |
---|
Min. Bend Radius/Minor Axis | 2.4 in |
---|
Standards
CPR Euroclass | Eca |
---|
RG Type | 59 |
---|
Applicable Environmental and Other Programs
Environmental Space | Indoor (Not Riser or Plenum) |
---|
EU Directive 2000/53/EC (ELV) | Yes |
---|
EU Directive 2003/11/EC (BFR) | Yes |
---|
EU Directive 2011/65/EU (RoHS 2) | Yes |
---|
EU Directive 2012/19/EU (WEEE) | Yes |
---|
EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
---|
EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
---|
EU CE Mark | Yes |
---|
MII Order #39 (China RoHS) | Yes |
---|
Suitability
Suitability - Aerial | No |
---|
Suitability - Burial | No |
---|
Suitability - Hazardous Locations | No |
---|
Suitability - Indoor | Yes |
---|
Suitability - Outdoor | No |
---|
Suitability - Sunlight Resistance | No |
---|
Plenum/Non-Plenum
Product Notes
Notes | Not recommended for RF use. Nominal voltage breakdown conductor to shield: 30 kV rms. Nominal voltage breakdown jacket (shield to water): 30 kV rms. |
---|
History
Update and Revision | Revision Number: 0.240 Revision Date: 12-19-2022 |
---|
Documentation
Product Bulletins
Catalogs
Tools
Data Sheets