15 AWG stranded (19x27) .064" bare copper conductor, foam HDPE insulation, paper tape separator, bare copper braid shields (90% and 80% coverage), CSPE - Chlorosulphonated Polyethylene jacket.
Specifications
Specifications
Physical Characteristics (Overall)
Conductor
AWG | Stranding | Material | Nominal Diameter | No. of Coax |
---|
15 | 19x27 | BC - Bare Copper | 0.064 in | 1 |
Insulation
Material | Nominal Diameter |
---|
PE - Polyethylene (Foam) | 0.312 in |
Inner Shield
Type | Material | Coverage [%] |
---|
Braid | Bare Copper (BC) | 90% |
Inner Jacket
Material | Nominal Diameter |
---|
PE - Polyethylene | 0.391 in |
Outer Shield
Type | Material | Coverage [%] |
---|
Braid | Bare Copper (BC) | 80% |
Outer Jacket
Material | Nominal Diameter |
---|
CSPE - Chlorosulphonated Polyethylene | 0.52 in |
Electrical Characteristics
Conductor DCR
Nominal Conductor DCR | Nominal Conductor DCR Conductor Resistance | Nominal Inner Shield DCR | Nominal Outer Shield DCR |
---|
3.1 Ohm/1000ft | 3.1 Ohm/1000ft | 1.6 Ohm/1000ft | 1.6 Ohm/1000ft |
Capacitance
Nom. Capacitance Conductor to Shield |
---|
17.3 pF/ft |
Inductance
Nominal Inductance |
---|
0.097 µH/ft |
Impedance
Nominal Characteristic Impedance |
---|
75 Ohm |
Return Loss
Frequency [MHz] | Minimum Return (RL) |
---|
5-450 MHz | 21 dB |
High Frequency (Nominal/Typical)
Frequency [MHz] | Nom. Insertion Loss |
---|
1 MHz | 0.1 dB/100ft |
3.6 MHz | 0.3 dB/100ft |
10 MHz | 0.5 dB/100ft |
71.5 MHz | 1.2 dB/100ft |
135 MHz | 1.8 dB/100ft |
270 MHz | 2.6 dB/100ft |
360 MHz | 3.1 dB/100ft |
540 MHz | 3.9 dB/100ft |
720 MHz | 4.7 dB/100ft |
750 MHz | 4.8 dB/100ft |
1000 MHz | 5.7 dB/100ft |
Delay
Nominal Delay | Nominal Velocity of Propagation (VP) [%] |
---|
1.3 ns/ft | 78% |
Voltage
Non-UL Voltage Rating | UL Voltage Rating |
---|
300 V RMS | 30 V RMS |
Electrical Characteristics Notes | Nominal Capacitance 1st Shield to 2nd Shield: 205 pf/ft. |
---|
Other Electrical Characteristic 2 | Nominal Voltage Breakdown: 20K V RMS |
---|
Temperature Range
Non-UL Temp Rating | 75°C |
---|
UL Temp Rating | 60°C |
---|
Operating Temperature Range | -20°C To +75°C |
---|
Mechanical Characteristics
Bulk Cable Weight | 135 lbs/1000ft |
---|
Max. Pull Tension | 239 lbs |
---|
Min. Bend Radius/Minor Axis | 5.25 in |
---|
Standards
UL AWM Style Compliance | AWM 1641 (30 V 60°C) |
---|
CPR Euroclass | Eca |
---|
RG Type | 11 |
---|
Applicable Environmental and Other Programs
Environmental Space | Indoor/Outdoor |
---|
EU Directive 2000/53/EC (ELV) | Yes |
---|
EU Directive 2011/65/EU (RoHS 2) | Yes |
---|
EU Directive 2012/19/EU (WEEE) | Yes |
---|
EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
---|
EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
---|
EU CE Mark | No |
---|
MII Order #39 (China RoHS) | Yes |
---|
Suitability
Suitability - Aerial | Yes - When supported by messenger wire |
---|
Suitability - Burial | Yes |
---|
Suitability - Indoor | Yes |
---|
Suitability - Outdoor | Yes |
---|
Flammability, LS0H, Toxicity Testing
UL Flammability | VW-1 |
---|
Other Flammability | UL2556 |
---|
UL voltage rating | 30 V RMS |
---|
Plenum/Non-Plenum
Related Part Numbers
Footnote | C - CRATE REEL PUT-UP. |
---|
History
Update and Revision | Revision Number: 0.395 Revision Date: 12-19-2022 |
---|
Documentation
Product Bulletins
Guide
Data Sheets