RG-6, 18 AWG solid .040" bare copper conductor, gas-injected foam HDPE insulation, Duofoil® shield, tinned copper braid shield (60% coverage), LSZH jacket.
Specifications
Specifications
Physical Characteristics (Overall)
Conductor
AWG | Stranding | Material | Nominal Diameter | No. of Coax |
---|
18 | Solid | BC - Bare Copper | 0.04 in | 1 |
Insulation
Material | Nominal Diameter |
---|
PE - Polyethylene (Foam) | 0.18 in |
Outer Shield
Type | Layer | Material | Material Trade Name | Coverage [%] |
---|
Tape | 1 | Tri-Laminate (Alum+Poly+Alum) | Duofoil® | 100% |
Braid | 2 | Tinned Copper (TC) | | 60% |
Outer Jacket
Material | Nominal Diameter |
---|
LSZH - Low Smoke Zero Halogen (Flame Retardant) | 0.27 in |
Electrical Characteristics
Conductor DCR
Nominal Conductor DCR | Outer Conductor DCR |
---|
6.4 Ohm/1000ft | 5.6 Ohm/1000ft |
Capacitance
Nom. Capacitance Conductor to Shield |
---|
16.2 pF/ft |
Inductance
Nominal Inductance |
---|
0.106 µH/ft |
Impedance
Nominal Characteristic Impedance |
---|
75 Ohm |
Return Loss
Frequency [MHz] | Minimum Return (RL) |
---|
5-450 MHz | 23 dB |
High Frequency (Nominal/Typical)
Frequency [MHz] | Nom. Insertion Loss |
---|
1 MHz | 0.3 dB/100ft |
5 MHz | 0.54 dB/100ft |
10 MHz | 0.7 dB/100ft |
50 MHz | 1.5 dB/100ft |
100 MHz | 2 dB/100ft |
200 MHz | 2.8 dB/100ft |
400 MHz | 4 dB/100ft |
Delay
Nominal Delay | Nominal Velocity of Propagation (VP) [%] |
---|
1.24 ns/ft | 82% |
Voltage
Voltage Rating [V] |
---|
300 V RMS |
Temperature Range
Operating Temperature Range | -30°C To +75°C |
---|
Mechanical Characteristics
Bulk Cable Weight | 36 lbs/1000ft |
---|
Max. Pull Tension | 44 lbs |
---|
Min. Bend Radius/Minor Axis | 2.7 in |
---|
Standards
Applicable Environmental and Other Programs
Environmental Space | Outdoor - Aerial |
---|
EU Directive 2000/53/EC (ELV) | Yes |
---|
EU Directive 2003/11/EC (BFR) | Yes |
---|
EU Directive 2011/65/EU (RoHS 2) | Yes |
---|
EU Directive 2012/19/EU (WEEE) | Yes |
---|
EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
---|
EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
---|
EU CE Mark | Yes |
---|
Suitability
Suitability - Aerial | Yes - Black only, when supported by messenger wire |
---|
Suitability - Burial | No |
---|
Suitability - Hazardous Locations | No |
---|
Suitability - Indoor | Yes |
---|
Suitability - Outdoor | Yes - Black only |
---|
Plenum/Non-Plenum
History
Update and Revision | Revision Number: 0.107 Revision Date: 04-08-2022 |
---|
Documentation
Product Bulletins
Catalogs
Tools
Data Sheets