RG-8/U type, 13 AWG stranded (7x21) .085" bare copper conductor, polyethylene insulation, bare copper braid shield (95% coverage), non-contaminating PVC jacket.
Specifications
Specifications
Physical Characteristics (Overall)
Conductor
| AWG | Stranding | Material | Nominal Diameter | No. of Coax |
|---|
| 13 | 7x21 | BC - Bare Copper | 0.085 in | 1 |
Insulation
| Material | Nominal Diameter | Nominal Wall Thickness |
|---|
| PE - Polyethylene | 0.285 in | 0.285 in |
Outer Shield
| Type | Material | Coverage [%] |
|---|
| Braid | Bare Copper (BC) | 95% |
Outer Jacket
| Material | Nominal Diameter |
|---|
| PVC - Polyvinyl Chloride (Non-Contaminating) | 0.405 in |
Electrical Characteristics
Conductor DCR
| Nominal Conductor DCR | Nominal Conductor DCR Conductor Resistance | Nominal Outer Shield DCR | Outer Conductor DCR |
|---|
| 1.9 Ohm/1000ft | 1.9 Ohm/1000ft | 1.2 Ohm/1000ft | 1.2 Ohm/1000ft |
Capacitance
| Nom. Capacitance Conductor to Shield |
|---|
| 28.5 pF/ft |
Inductance
| Nominal Inductance |
|---|
| 0.079 µH/ft |
Impedance
| Nominal Characteristic Impedance |
|---|
| 52 Ohm |
High Frequency (Nominal/Typical)
| Frequency [MHz] | Nom. Insertion Loss |
|---|
| 1 MHz | 0.2 dB/100ft |
| 10 MHz | 0.6 dB/100ft |
| 50 MHz | 1.3 dB/100ft |
| 100 MHz | 1.9 dB/100ft |
| 200 MHz | 2.8 dB/100ft |
| 400 MHz | 4.2 dB/100ft |
| 700 MHz | 5.9 dB/100ft |
| 900 MHz | 6.9 dB/100ft |
| 1000 MHz | 7.4 dB/100ft |
| 4000 MHz | 23.2 dB/100ft |
Delay
| Nominal Delay | Nominal Velocity of Propagation (VP) [%] |
|---|
| 1.54 ns/ft | 66% |
Voltage
| Non-UL Voltage Rating | UL Voltage Rating |
|---|
| 3700 V RMS | 150 V RMS |
| 30 V RMS (UL AWM Style 1354) |
Temperature Range
| UL Temp Rating | 60°C |
|---|
| Operating Temperature Range | -40°C To +80°C |
|---|
Mechanical Characteristics
| Bulk Cable Weight | 105 lbs/1000ft |
|---|
| Max. Pull Tension | 190 lbs |
|---|
| Min. Bend Radius/Minor Axis | 4 in |
|---|
Standards
| NEC/(UL) Compliance | CMX |
|---|
| CEC/C(UL) Compliance | CMX |
|---|
| UL AWM Style Compliance | AWM 1354 (30 V 60°C) |
|---|
| RG Type | 8 |
|---|
Applicable Environmental and Other Programs
| Environmental Space | Indoor (Not Riser or Plenum) |
|---|
| EU Directive 2000/53/EC (ELV) | Yes |
|---|
| EU Directive 2003/11/EC (BFR) | Yes |
|---|
| EU Directive 2011/65/EU (RoHS 2) | Yes |
|---|
| EU Directive 2012/19/EU (WEEE) | Yes |
|---|
| EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
|---|
| EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
|---|
| EU CE Mark | Yes |
|---|
| MII Order #39 (China RoHS) | Yes |
|---|
Suitability
| Suitability - Aerial | Yes |
|---|
| Suitability - Indoor | Yes |
|---|
| Suitability - Outdoor | Yes |
|---|
Flammability, LS0H, Toxicity Testing
| UL Flammability | VW-1 |
|---|
| UL voltage rating | 150 V RMS |
|---|
Plenum/Non-Plenum
Related Part Numbers
| Footnote | C - CRATE REEL PUT-UP. |
|---|
History