RG-122/U, 22 AWG stranded (27x36) .030" tinned copper conductor, polyethylene insulation, tinned copper braid shield (95% coverage), non-contaminating PVC jacket, commercial non-QPL product.
Specifications
Specifications
Physical Characteristics (Overall)
Conductor
AWG | Stranding | Material | Nominal Diameter | No. of Coax |
---|
22 | Stranded | TC - Tinned Copper | 0.03 in | 1 |
Insulation
Material | Nominal Diameter |
---|
PE - Polyethylene | 0.096 in |
Outer Shield
Type | Layer | Material | Coverage [%] |
---|
Braid | 1 | Tinned Copper (TC) | 95% |
Outer Jacket
Material | Nominal Diameter |
---|
PVC - Polyvinyl Chloride (Non-Contaminating) | 0.16 in |
Electrical Characteristics
Conductor DCR
Nominal Conductor DCR | Nominal Conductor DCR Conductor Resistance | Nominal Outer Shield DCR | Outer Conductor DCR |
---|
17.1 Ohm/1000ft | 17.1 Ohm/1000ft | 5.2 Ohm/1000ft | 5.2 Ohm/1000ft |
Capacitance
Nom. Capacitance Conductor to Shield |
---|
30.8 pF/ft |
Inductance
Nominal Inductance |
---|
0.077 µH/ft |
Impedance
Nominal Characteristic Impedance |
---|
50 Ohm |
High Frequency (Nominal/Typical)
Frequency [MHz] | Nom. Insertion Loss |
---|
1 MHz | 0.4 dB/100ft |
10 MHz | 1.7 dB/100ft |
50 MHz | 4.5 dB/100ft |
100 MHz | 7 dB/100ft |
200 MHz | 11 dB/100ft |
400 MHz | 16.5 dB/100ft |
700 MHz | 23.5 dB/100ft |
900 MHz | 27.3 dB/100ft |
1000 MHz | 29 dB/100ft |
Delay
Nominal Delay | Nominal Velocity of Propagation (VP) [%] |
---|
1.54 ns/ft | 66% |
Voltage
Description | Non-UL Voltage Rating | UL Voltage Rating | Voltage Rating [V] |
---|
1400 V RMS | 1400 V RMS (Mil-Spec) | 300 V RMS (CMX) | 30V RMS (UL AWM Stype 1354) |
| | 30 V RMS (UL AWM Style 1354) | |
Temperature Range
UL Temp Rating | 60°C |
---|
Operating Temperature Range | -40°C To +60°C |
---|
Mechanical Characteristics
UV Resistance | Yes - Black only |
---|
Bulk Cable Weight | 18 lbs/1000ft |
---|
Max. Pull Tension | 38 lbs |
---|
Min. Bend Radius/Minor Axis | 1.75 in |
---|
Standards
NEC/(UL) Compliance | CMX |
---|
CEC/C(UL) Compliance | CMX |
---|
UL AWM Style Compliance | AWM 1354 (30 V 60°C) |
---|
CPR Euroclass | Eca |
---|
RG Type | 122 |
---|
Military Compliance | Commercial, non-QPL product (M17/157-00001) |
---|
Qualified Products List (QPL) | No |
---|
Applicable Environmental and Other Programs
Environmental Space | Indoor (Not Riser or Plenum) |
---|
EU Directive 2000/53/EC (ELV) | Yes |
---|
EU Directive 2003/11/EC (BFR) | Yes |
---|
EU Directive 2011/65/EU (RoHS 2) | Yes |
---|
EU Directive 2012/19/EU (WEEE) | Yes |
---|
EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
---|
EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
---|
EU CE Mark | Yes |
---|
MII Order #39 (China RoHS) | Yes |
---|
Suitability
Suitability - Aerial | Yes - Black only, when supported by messenger wire |
---|
Suitability - Burial | No |
---|
Suitability - Hazardous Locations | No |
---|
Suitability - Indoor | Yes |
---|
Suitability - Outdoor | Yes - Black only |
---|
Flammability, LS0H, Toxicity Testing
UL voltage rating | 300 V RMS (CMX) |
---|
Plenum/Non-Plenum
History
Update and Revision | Revision Number: 0.437 Revision Date: 12-19-2022 |
---|
Documentation
Product Bulletins
Solution Guides
Tools
White Papers
Training
Data Sheets