Composite, RG-59 22 AWG BC Coax, stranded (7x30), BC braid 95% coverage, 1 PR 22 AWG TC, stranded (7x30), w/drain wire, PVC jacket.
Specifications
Specifications
Physical Characteristics (Overall)
Conductor
Element | AWG | Stranding | Material | Nominal Diameter | No. of Pairs | No. of Coax |
---|
Coax(es) | 22 | Stranded | BC - Bare Copper | 0.03 in | | 1 |
Pair(s) | 22 | 7x30 | TC - Tinned Copper | 0.03 in | 1 | |
Insulation
Element | Material | Nominal Diameter |
---|
Coax(es) | PE - Polyethylene (Foam) | 0.146 in |
Pair(s) | PVC - Polyvinyl Chloride | 0.054 in |
Color Chart
Inner Shield
Element | Type | Material | Material Trade Name | Coverage [%] | Drainwire Material | Drainwire Diameter | Drainwire AWG | Drainwire Construction n x D |
---|
Coax(es) | Braid | Bare Copper (BC) | | 95% | TC - Tinned Copper | 0.03 in | 22 | 7x30 |
Pair(s) | Tape | Bi-Laminate (Alum+Poly) | Beldfoil® (Z-Fold®) | 100% | | | | |
Outer Jacket
Material | Nominal Diameter |
---|
PVC - Polyvinyl Chloride | 0.47 in |
Electrical Characteristics
Conductor DCR
Nominal Conductor DCR Conductor Resistance | Nominal Inner Shield DCR | Nominal Outer Shield DCR |
---|
15 Ohm/1000ft | 2.6 Ohm/1000ft | 11 Ohm/1000ft |
Capacitance
Element | Nom. Capacitance Conductor to Conductor | Nom. Capacitance Conductor to Shield |
---|
Coax(es) | 51 pF/ft | 17.3 pF/ft |
Pair(s) | | 95.5 pF/ft |
Inductance
Nominal Inductance |
---|
0.09 µH/ft |
Impedance
Element | Nominal Characteristic Impedance |
---|
Coax(es) | 75 Ohm |
High Frequency (Nominal/Typical)
Element | Frequency [MHz] | Nom. Insertion Loss |
---|
Coax(es) | 1 MHz | 0.3 dB/100ft |
| 5 MHz | 0.7 dB/100ft |
| 10 MHz | 1 dB/100ft |
| 50 MHz | 2.1 dB/100ft |
| 100 MHz | 3 dB/100ft |
Delay
Element | Nominal Delay | Nominal Velocity of Propagation (VP) [%] |
---|
Coax(es) | 1.3 ns/ft | 78% |
Voltage
UL Voltage Rating |
---|
30 V RMS |
Electrical Characteristics Notes | Coax Nominal Voltage Breakdown Jacket (Shield to Ground) = 22kV RMS |
---|
Temperature Range
Non-UL Temp Rating | 60°C |
---|
Operating Temperature Range | -40°C To +60°C |
---|
Mechanical Characteristics
Bulk Cable Weight | 58 lbs/1000ft |
---|
Max. Pull Tension | 68 lbs |
---|
Min. Bend Radius/Minor Axis | 2.5 in |
---|
Standards
NEC/(UL) Compliance | CL2 |
---|
UL AWM Style Compliance | AWM 20006 |
---|
CPR Euroclass | Eca |
---|
RG Type | 59 |
---|
Applicable Environmental and Other Programs
Environmental Space | Indoor (Not Riser or Plenum) |
---|
EU Directive 2000/53/EC (ELV) | Yes |
---|
EU Directive 2003/11/EC (BFR) | Yes |
---|
EU Directive 2011/65/EU (RoHS 2) | Yes |
---|
EU Directive 2012/19/EU (WEEE) | Yes |
---|
EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
---|
EU Directive Compliance | Yes |
---|
EU CE Mark | No |
---|
MII Order #39 (China RoHS) | Yes |
---|
Suitability
Flammability, LS0H, Toxicity Testing
UL Flammability | UL1685 UL Loading |
---|
UL voltage rating | 30 V RMS |
---|
Plenum/Non-Plenum
Related Part Numbers
Footnote | C - CRATE REEL PUT-UP. |
---|
Product Notes
Notes | Simaese Type Construction. |
---|
History
Update and Revision | Revision Number: 0.355 Revision Date: 05-05-2023 |
---|
Documentation
Product Bulletins
Catalogs
Tools