124 Ohm Twinax, 25 AWG stranded (7x33) tinned copper conductors, polyethylene insulation, Beldfoil® shield (100% coverage), stranded tinned copper drain wire, PVC jacket.
Specifications
Specifications
Physical Characteristics (Overall)
Conductor
AWG | Stranding | Material | Nominal Diameter | No. of Pairs |
---|
25 | 7x33 | TC - Tinned Copper | 0.021 in | 1 |
Insulation
Material | Nominal Wall Thickness |
---|
PE - Polyethylene | 0.031 in |
Color Chart
Outer Shield
Type | Material | Material Trade Name | Coverage [%] | Drainwire Material | Drainwire AWG | Drainwire Construction n x D |
---|
Tape | Bi-Laminate (Alum+Poly) | Beldfoil® | 100% | TC - Tinned Copper | 22 | 7x30 |
Outer Jacket
Material | Nominal Diameter | Nominal Wall Thickness |
---|
PVC - Polyvinyl Chloride | 0.24 in | 0.035 in |
Construction and Dimensions
Stranding
Electrical Characteristics
Conductor DCR
Nominal Conductor DCR | Nominal Conductor DCR Conductor Resistance | Nominal Outer Shield DCR |
---|
31.8 Ohm/1000ft | 31.8 Ohm/1000ft | 12 Ohm/1000ft |
Capacitance
Nom. Capacitance Conductor to Conductor | Nom. Capacitance Conductor to Other Conductor to Shield |
---|
12.2 pF/ft | 22 pF/ft |
Inductance
Nominal Inductance |
---|
0.188 µH/ft |
Impedance
Nominal Characteristic Impedance |
---|
124 Ohm |
High Frequency (Nominal/Typical)
Frequency [MHz] | Nom. Insertion Loss |
---|
1 MHz | 0.6 dB/100ft |
10 MHz | 1.7 dB/100ft |
50 MHz | 3.6 dB/100ft |
100 MHz | 5 dB/100ft |
200 MHz | 6.9 dB/100ft |
400 MHz | 9.6 dB/100ft |
Delay
Max. Delay Skew | Nominal Delay | Nominal Velocity of Propagation (VP) [%] |
---|
66 ns/100m | 1.54 ns/ft | 66% |
High Frequency
Frequency [MHz] |
---|
1 MHz |
10 MHz |
50 MHz |
100 MHz |
200 MHz |
400 MHz |
Voltage
UL Description | UL Voltage Rating |
---|
UL AWM Style 2092 | 300 V RMS |
Temperature Range
UL Temp Rating | 60°C (UL AWM Style 2092) |
---|
Operating Temperature Range | -20°C To +60°C |
---|
Mechanical Characteristics
Bulk Cable Weight | 25 lbs/1000ft |
---|
Max. Pull Tension | 17 lbs |
---|
Min. Bend Radius/Minor Axis | 2.5 in |
---|
Standards
NEC/(UL) Compliance | CM |
---|
CEC/C(UL) Compliance | CM |
---|
UL AWM Style Compliance | AWM 2092 (300 V 60°C) |
---|
CPR Euroclass | Eca |
---|
Applicable Environmental and Other Programs
EU Directive Compliance | Yes |
---|
EU CE Mark | Yes |
---|
MII Order #39 (China RoHS) | Yes |
---|
Flammability, LS0H, Toxicity Testing
UL Flammability | UL1685 UL Loading |
---|
IEC Flammability | IEC 60332-1-2 |
---|
UL voltage rating | 300 V RMS |
---|
Plenum/Non-Plenum
Related Part Numbers
Footnote | C - CRATE REEL PUT-UP. |
---|
History
Update and Revision | Revision Number: 0.425 Revision Date: 05-05-2023 |
---|
Documentation
Product Bulletins
Catalogs
Data Sheets