20 AWG solid .032" bare copper-covered steel conductor, foam polyethylene insulation, bare copper braid shield (95% coverage), PVC jacket.
Specifications
Specifications
Physical Characteristics (Overall)
Conductor
AWG | Stranding | Material | Nominal Diameter | No. of Coax |
---|
20 | Solid | BCCS - Bare Copper Covered Steel | 0.032 in | 1 |
Insulation
Material | Nominal Diameter |
---|
PE - Polyethylene (Foam) | 0.143 in |
Outer Shield
Type | Material | Coverage [%] |
---|
Braid | Bare Copper (BC) | 95% |
Outer Jacket
Material | Nominal Diameter |
---|
PVC - Polyvinyl Chloride | 0.235 in |
Electrical Characteristics
Conductor DCR
Nominal Conductor DCR | Nominal Conductor DCR Conductor Resistance | Nominal Outer Shield DCR | Outer Conductor DCR |
---|
44.5 Ohm/1000ft | 44.5 Ohm/1000ft | 3.5 Ohm/1000ft | 3.5 Ohm/1000ft |
Capacitance
Nom. Capacitance Conductor to Shield |
---|
16.3 pF/ft |
Inductance
Nominal Inductance |
---|
0.097 µH/ft |
Impedance
Nominal Characteristic Impedance |
---|
75 Ohm |
Return Loss
Frequency [MHz] | Min. Structural Return Loss (SRL) |
---|
5-450 MHz | 23 dB |
High Frequency (Nominal/Typical)
Frequency [MHz] | Nom. Insertion Loss |
---|
1 MHz | 0.6 dB/100ft |
10 MHz | 1 dB/100ft |
50 MHz | 2.1 dB/100ft |
100 MHz | 3 dB/100ft |
200 MHz | 4.5 dB/100ft |
400 MHz | 6.6 dB/100ft |
700 MHz | 8.9 dB/100ft |
900 MHz | 10.1 dB/100ft |
1000 MHz | 10.9 dB/100ft |
Delay
Nominal Delay | Nominal Velocity of Propagation (VP) [%] |
---|
1.24 ns/ft | 82% |
Voltage
UL Voltage Rating |
---|
300 V RMS |
Temperature Range
UL Temp Rating | 80°C |
---|
Operating Temperature Range | -40°C To +80°C |
---|
Mechanical Characteristics
Bulk Cable Weight | 31 lbs/1000ft |
---|
Max. Pull Tension | 86 lbs |
---|
Min. Bend Radius/Minor Axis | 2.5 in |
---|
Standards
NEC/(UL) Compliance | CM |
---|
CEC/C(UL) Compliance | CM |
---|
RG Type | 59 |
---|
Series Type | 59 |
---|
Applicable Environmental and Other Programs
Environmental Space | Indoor/Outdoor |
---|
EU Directive 2000/53/EC (ELV) | Yes |
---|
EU Directive 2003/11/EC (BFR) | Yes |
---|
EU Directive 2011/65/EU (RoHS 2) | Yes |
---|
EU Directive 2012/19/EU (WEEE) | Yes |
---|
EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
---|
EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
---|
EU CE Mark | No |
---|
MII Order #39 (China RoHS) | Yes |
---|
Suitability
Suitability - Indoor | Yes |
---|
Suitability - Outdoor | Yes |
---|
Flammability, LS0H, Toxicity Testing
UL Flammability | UL1685 UL Loading |
---|
UL voltage rating | 300 V RMS |
---|
Plenum/Non-Plenum
Related Part Numbers
Footnote | C - CRATE REEL PUT-UP. |
---|
History
Update and Revision | Revision Number: 0.337 Revision Date: 11-09-2022 |
---|
Documentation
Product Bulletins
Catalogs
Tools
Data Sheets