RG-58/U type, 20 AWG solid .033" bare copper conductor, polyethylene insulation, Duobond® II + tinned copper braid shield (55% coverage), PVC jacket.
Specifications
Specifications
Physical Characteristics (Overall)
Conductor
| AWG | Stranding | Material | Nominal Diameter | No. of Coax |
|---|
| 20 | Solid | BC - Bare Copper | 0.033 in | 1 |
Insulation
| Material | Nominal Diameter |
|---|
| PE - Polyethylene | 0.114 in |
Outer Shield
| Type | Layer | Material | Material Trade Name | Coverage [%] |
|---|
| Tape | 1 | Tri-Laminate (Alum+Poly+Alum) | Duofoil® | 100% |
| Braid | 2 | Tinned Copper (TC) | | 55% |
Outer Jacket
| Material | Nominal Diameter |
|---|
| PVC - Polyvinyl Chloride | 0.193 in |
Electrical Characteristics
Conductor DCR
| Nominal Conductor DCR | Nominal Conductor DCR Conductor Resistance | Nominal Outer Shield DCR | Outer Conductor DCR |
|---|
| 9.4 Ohm/1000ft | 9.4 Ohm/1000ft | 8 Ohm/1000ft | 8 Ohm/1000ft |
Capacitance
| Nom. Capacitance Conductor to Shield |
|---|
| 30.8 pF/ft |
Inductance
| Nominal Inductance |
|---|
| 0.09 µH/ft |
Impedance
| Nominal Characteristic Impedance |
|---|
| 50 Ohm |
High Frequency (Nominal/Typical)
| Frequency [MHz] | Nom. Insertion Loss |
|---|
| 1 MHz | 0.46 dB/100ft |
| 10 MHz | 1.4 dB/100ft |
| 50 MHz | 2.8 dB/100ft |
| 100 MHz | 3.8 dB/100ft |
| 200 MHz | 5.4 dB/100ft |
| 400 MHz | 7.9 dB/100ft |
| 700 MHz | 11.1 dB/100ft |
| 900 MHz | 12.8 dB/100ft |
| 1000 MHz | 13.9 dB/100ft |
Delay
| Nominal Delay | Nominal Velocity of Propagation (VP) [%] |
|---|
| 1.54 ns/ft | 66% |
Voltage
| Non-UL Voltage Rating | UL Voltage Rating |
|---|
| 1400 V RMS | 30 V RMS |
Temperature Range
| UL Temp Rating | 60°C |
|---|
| Operating Temperature Range | -40°C To +60°C |
|---|
Mechanical Characteristics
| Bulk Cable Weight | 20 lbs/1000ft |
|---|
| Max. Pull Tension | 12.4 lbs |
|---|
| Min. Bend Radius/Minor Axis | 2 in |
|---|
Standards
| UL AWM Style Compliance | AWM 1354 (30 V 60°C) |
|---|
| CPR Euroclass | Eca |
|---|
| RG Type | 58 |
|---|
Applicable Environmental and Other Programs
| Environmental Space | Indoor/Outdoor |
|---|
| EU Directive 2000/53/EC (ELV) | Yes |
|---|
| EU Directive 2003/11/EC (BFR) | Yes |
|---|
| EU Directive 2011/65/EU (RoHS 2) | Yes |
|---|
| EU Directive 2012/19/EU (WEEE) | Yes |
|---|
| EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
|---|
| EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
|---|
| EU CE Mark | No |
|---|
| MII Order #39 (China RoHS) | Yes |
|---|
Suitability
| Suitability - Indoor | Yes |
|---|
| Suitability - Outdoor | Yes |
|---|
Flammability, LS0H, Toxicity Testing
| IEC Flammability | IEC 60332-1-2 |
|---|
| UL voltage rating | 30 V RMS |
|---|
Plenum/Non-Plenum
Related Part Numbers
| Footnote | C - CRATE REEL PUT-UP. |
|---|
History
| Update and Revision | Revision Number: 0.457 Revision Date: 12-19-2022 |
|---|
Documentation
Product Bulletins
Solution Guides
Tools
White Papers
Training