RG-58/U type, 20 AWG solid .033" bare copper conductor, polyethylene insulation, Duobond® II + tinned copper braid shield (55% coverage), PVC jacket.
Specifications
Specifications
Physical Characteristics (Overall)
Conductor
AWG | Stranding | Material | Nominal Diameter | No. of Coax |
---|
20 | Solid | BC - Bare Copper | 0.033 in | 1 |
Insulation
Material | Nominal Diameter |
---|
PE - Polyethylene | 0.114 in |
Outer Shield
Type | Layer | Material | Material Trade Name | Coverage [%] |
---|
Tape | 1 | Tri-Laminate (Alum+Poly+Alum) | Duofoil® | 100% |
Braid | 2 | Tinned Copper (TC) | | 55% |
Outer Jacket
Material | Nominal Diameter |
---|
PVC - Polyvinyl Chloride | 0.193 in |
Electrical Characteristics
Conductor DCR
Nominal Conductor DCR | Nominal Conductor DCR Conductor Resistance | Nominal Outer Shield DCR | Outer Conductor DCR |
---|
9.4 Ohm/1000ft | 9.4 Ohm/1000ft | 8 Ohm/1000ft | 8 Ohm/1000ft |
Capacitance
Nom. Capacitance Conductor to Shield |
---|
30.8 pF/ft |
Inductance
Nominal Inductance |
---|
0.09 µH/ft |
Impedance
Nominal Characteristic Impedance |
---|
50 Ohm |
High Frequency (Nominal/Typical)
Frequency [MHz] | Nom. Insertion Loss |
---|
1 MHz | 0.46 dB/100ft |
10 MHz | 1.4 dB/100ft |
50 MHz | 2.8 dB/100ft |
100 MHz | 3.8 dB/100ft |
200 MHz | 5.4 dB/100ft |
400 MHz | 7.9 dB/100ft |
700 MHz | 11.1 dB/100ft |
900 MHz | 12.8 dB/100ft |
1000 MHz | 13.9 dB/100ft |
Delay
Nominal Delay | Nominal Velocity of Propagation (VP) [%] |
---|
1.54 ns/ft | 66% |
Voltage
Non-UL Voltage Rating | UL Voltage Rating |
---|
1400 V RMS | 30 V RMS |
Temperature Range
UL Temp Rating | 60°C |
---|
Operating Temperature Range | -40°C To +60°C |
---|
Mechanical Characteristics
Bulk Cable Weight | 20 lbs/1000ft |
---|
Max. Pull Tension | 12.4 lbs |
---|
Min. Bend Radius/Minor Axis | 2 in |
---|
Standards
UL AWM Style Compliance | AWM 1354 (30 V 60°C) |
---|
CPR Euroclass | Eca |
---|
RG Type | 58 |
---|
Applicable Environmental and Other Programs
Environmental Space | Indoor/Outdoor |
---|
EU Directive 2000/53/EC (ELV) | Yes |
---|
EU Directive 2003/11/EC (BFR) | Yes |
---|
EU Directive 2011/65/EU (RoHS 2) | Yes |
---|
EU Directive 2012/19/EU (WEEE) | Yes |
---|
EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
---|
EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
---|
EU CE Mark | No |
---|
MII Order #39 (China RoHS) | Yes |
---|
Suitability
Suitability - Indoor | Yes |
---|
Suitability - Outdoor | Yes |
---|
Flammability, LS0H, Toxicity Testing
IEC Flammability | IEC 60332-1-2 |
---|
UL voltage rating | 30 V RMS |
---|
Plenum/Non-Plenum
Related Part Numbers
Footnote | C - CRATE REEL PUT-UP. |
---|
History
Update and Revision | Revision Number: 0.457 Revision Date: 12-19-2022 |
---|
Documentation
Product Bulletins
Solution Guides
Tools
White Papers
Training
Data Sheets