Audio, Control & Instrument Cable, 22 AWG solid tinned copper conductors, PVC insulation, twisted pairs, overall Beldfoil® shield (100% coverage), 22 AWG stranded tinned copper drain wire, PVC jacket.
Specifications
Specifications
Product Overview
Suitable Applications | low voltage analog signals (4-20ma, 0-10v, ...); low voltage digital control (24v, …); line level audio; computer communication; panel wiring |
---|
Physical Characteristics (Overall)
Conductor
AWG | Stranding | Material | No. of Pairs |
---|
22 | Solid | TC - Tinned Copper | 15 |
Insulation
Material | Nominal Wall Thickness |
---|
PVC - Polyvinyl Chloride | 0.013 in |
Color Chart
Number | Color |
---|
1 | Black & Red |
2 | Black & White |
3 | Black & Green |
4 | Black & Blue |
5 | Black & Yellow |
6 | Black & Brown |
7 | Black & Orange |
8 | Red & White |
9 | Red & Green |
10 | Red & Blue |
11 | Red & Yellow |
12 | Red & Brown |
13 | Red & Orange |
14 | Green & White |
15 | Green & Blue |
Outer Shield
Type | Material | Material Trade Name | Coverage [%] | Drainwire Material | Drainwire AWG | Drainwire Construction n x D |
---|
Tape | Bi-Laminate (Alum+Poly) | Beldfoil® | 100% | TC - Tinned Copper | 22 | 7x30 |
Outer Jacket
Material | Nominal Diameter | Nominal Wall Thickness |
---|
PVC - Polyvinyl Chloride | 0.449 in | 0.037 in |
Electrical Characteristics
Conductor DCR
Nominal Conductor DCR | Nominal Outer Shield DCR |
---|
16.5 Ohm/1000ft | 14 Ohm/1000ft |
Capacitance
Nom. Capacitance Conductor to Conductor | Nom. Capacitance Conductor to Shield |
---|
35 pF/ft | 50 pF/ft |
Inductance
Nominal Inductance |
---|
0.2 µH/ft |
Current
Max. Recommended Current [A] |
---|
1.4 Amps per Conductor at 25ºC |
Voltage
UL Voltage Rating |
---|
300 V RMS |
Temperature Range
UL Temp Rating | 80°C (UL AWM Style 2464) |
---|
Operating Temperature Range | -20°C To +80°C |
---|
Mechanical Characteristics
Bulk Cable Weight | 124 lbs/1000ft |
---|
Max. Pull Tension | 242 lbs |
---|
Min. Bend Radius/Minor Axis | 4.5 in |
---|
Standards
NEC/(UL) Compliance | CMG |
---|
CEC/C(UL) Compliance | CMG |
---|
UL AWM Style Compliance | AWM 2464 (300 V 80°C) |
---|
CPR Euroclass | Eca |
---|
Applicable Environmental and Other Programs
EU Directive 2000/53/EC (ELV) | Yes |
---|
EU Directive 2003/96/EC (BFR) | Yes |
---|
EU Directive 2011/65/EU (RoHS 2) | Yes |
---|
EU Directive 2012/19/EU (WEEE) | Yes |
---|
EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
---|
EU CE Mark | Yes |
---|
MII Order #39 (China RoHS) | Yes |
---|
Flammability, LS0H, Toxicity Testing
UL Flammability | UL1685 FT4 Loading |
---|
CSA Flammability | FT4 |
---|
IEC Flammability | IEC 60332-1-2 |
---|
UL voltage rating | 300 V RMS |
---|
Plenum/Non-Plenum
Related Part Numbers
Footnote | C - CRATE REEL PUT-UP. |
---|
History
Update and Revision | Revision Number: 0.336 Revision Date: 05-05-2023 |
---|
Documentation
Product Bulletins
Catalogs
Brochures
Data Sheets