Audio Snake Cable, 4 Pair 22 AWG tinned copper pairs, FEP insulation, drain, individually shielded with Beldfoil® bonded to numbered PVC jackets so both strip simulteaneously, Plenum Flamarrest® jackets, Banana Peel construction
Specifications
Specifications
Product Overview
Suitable Applications | Recording Studio, Radio Broadcast, Sports Stadium, Nurse Call |
---|
Physical Characteristics (Overall)
Conductor
AWG | Stranding | Material | Nominal Diameter | No. of Pairs |
---|
22 | 7x30 | TC - Tinned Copper | 0.0285 in | 4 |
Conductor Count | 8 |
---|
Total Number of Pairs | 4 |
---|
Insulation
Material | Nominal Diameter | Nominal Wall Thickness |
---|
FEP - Fluorinated Ethylene Propylene | 0.0425 in | 0.007 in |
Color Chart
Inner Jacket
Outer Shield
Type | Material | Material Trade Name | Coverage [%] | Drainwire Material | Drainwire Diameter | Drainwire AWG | Drainwire Construction n x D |
---|
Tape | Bi-Laminate (Alum+Poly) | Beldfoil® | 100% | TC - Tinned Copper | 0.030 in | 22 | 7x30 |
Outer Jacket
Material | Material Trade Name | Nominal Diameter | Nominal Wall Thickness |
---|
PVC - Polyvinyl Chloride | Flamarrest® | 0.127 in | 0.017 in |
Electrical Characteristics
Conductor DCR
Nominal Conductor DCR | Nominal Conductor DCR Conductor Resistance | Nominal Outer Shield DCR |
---|
14.1 Ohm/1000ft | 14.1 Ohm/1000ft | 14.3 Ohm/1000ft |
Capacitance
Nom. Capacitance Conductor to Conductor | Nom. Capacitance Conductor to Other Conductor to Shield |
---|
35 pF/ft | 67 pF/ft |
Inductance
Nominal Inductance |
---|
0.15 µH/ft |
Delay
Nominal Delay | Nominal Velocity of Propagation (VP) [%] |
---|
1.47 ns/ft | 69% |
Current
Max. Recommended Current [A] |
---|
2.9 Amps per Conductor at 25ºC |
Voltage
UL Voltage Rating |
---|
300 V RMS |
Temperature Range
UL Temp Rating | 60°C |
---|
Operating Temperature Range | -20°C To +75°C |
---|
Mechanical Characteristics
Bulk Cable Weight | 60 lbs/1000ft |
---|
Max. Pull Tension | 108 lbs |
---|
Min. Bend Radius/Minor Axis | 3.25 in |
---|
Standards
NEC/(UL) Compliance | CMP |
---|
CEC/C(UL) Compliance | CMP |
---|
Applicable Environmental and Other Programs
Environmental Space | Indoor - Plenum |
---|
EU Directive 2000/53/EC (ELV) | Yes |
---|
EU Directive 2003/11/EC (BFR) | Yes |
---|
EU Directive 2011/65/EU (RoHS 2) | Yes |
---|
EU Directive 2012/19/EU (WEEE) | Yes |
---|
EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
---|
EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
---|
EU CE Mark | Yes |
---|
MII Order #39 (China RoHS) | Yes |
---|
Suitability
Flammability, LS0H, Toxicity Testing
UL Flammability | NFPA 262 |
---|
CSA Flammability | FT6 |
---|
UL voltage rating | 300 V RMS |
---|
Plenum/Non-Plenum
Product Notes
Notes | The jacket and shield are bonded so both can be removed on automatic stripping equipment. Drain wire is inside foil shield. |
---|
History
Update and Revision | Revision Number: 0.366 Revision Date: 12-20-2022 |
---|
Documentation
Product Bulletins
Catalogs
Technical Resources
Data Sheets