9462 - Electronic, 2 C #22 Str TC, PVC Ins, OS, PVC Jkt, CMG
- SKU:
- 9462
- Shipping:
- Calculated at Checkout
Description
Electronic, 2 Conductor 22AWG (7x30) Tinned Copper, PVC Insulation, Overall Beldfoil® Shield, PVC Outer Jacket, CMG
Specifications
Specifications
Product Overview
Suitable Applications | low voltage analog signals (4-20ma, 0-10v, ...); low voltage digital control (24v, …); line level audio; computer communication; panel wiring |
---|
Construction Details
Conductor
Element | Number of Element | Size | Stranding | Material |
---|---|---|---|---|
Conductor(s) | 2 | 22 AWG | 7x30 | TC - Tinned Copper |
Insulation
Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code |
---|---|---|---|---|
Conductor(s) | PVC - Polyvinyl Chloride | 0.0155 in (0.394 mm) | 0.060 in (1.5 mm) | Black, Red |
Outer Shield
Shield Type | Material | Coverage | Drainwire Type | Notes |
---|---|---|---|---|
Tape | Bi-Laminate (Alum+Poly) | 100% | 22 AWG (7x30) TC | Foil-Out |
Outer Jacket
Material | Nom. Thickness | Nom. Diameter |
---|---|---|
PVC - Polyvinyl Chloride | 0.035 in (0.89 mm) | 0.194 in (4.93 mm) |
Overall Cable Diameter (Nominal) | 0.194 in (4.93 mm) |
---|
Electrical Characteristics
Electricals
Element | Nom. Conductor DCR | Nom. Capacitance Cond-to-Cond | Nom. Capacitance Cond-to-Other (Conds + Shield) | Nom. Characteristic Impedence | Max. Current |
---|---|---|---|---|---|
Conductor(s) | 16 Ohm/1000ft | 50 pF/ft (160 pF/m) | 90 pF/ft (300 pF/m) | 36 Ohm | 3 Amps per Conductor at 25ºC |
Voltage
UL Voltage Rating |
---|
300 V (CMG), 300 V (UL AWM 2464) |
Mechanical Characteristics
Temperature
UL Temperature | Operating |
---|---|
80°C | -30°C to +80°C |
Bend Radius
Stationary Min. | Installation Min. |
---|---|
1.9 in (48 mm) | 1.9 in (48 mm) |
Max. Pull Tension | 27 lbs (12 kg) |
---|---|
Bulk Cable Weight | 19 lbs/1000ft |
Standards and Compliance
Environmental Suitability | Indoor (Not Riser or Plenum), Indoor |
---|---|
Sustainability | CA Prop 65 |
Flammability / Reaction to Fire | UL 1685 FT4 Loading, FT4, IEC 60332-1-2 |
CPR Compliance | CPR Euroclass: Eca |
NEC / UL Compliance | Article 800, CMG |
AWM Compliance | AWM 2464 |
CEC / C(UL) Compliance | CMG |
European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
UK Regulation Compliance | UKCA Mark |
APAC Compliance | China RoHS II (GB/T 26572-2011) |
History
Update and Revision | Revision Number: 0.528 Revision Date: 01-20-2023 |
---|
Documentation
Product Bulletins
Catalogs
Brochures
Compliance Documentation
Data Sheets
Additional Information
Variant_Options: |
Item #|Color|UPC |
Variant_Options 9462 060100: |
9462 060100|Chrome|612825253464 |
Variant_Options 9462 0601000: |
9462 0601000|Chrome|612825253471 |
Variant_Options 9462 060500: |
9462 060500|Chrome|612825253488 |
Variant_Options 9462 0605000: |
9462 0605000|Chrome|612825253495 |
Variant_Options 9462 060U1000: |
9462 060U1000|Chrome|612825253440 |
Variant_Options 9462 060U500: |
9462 060U500|Chrome|612825253457 |