Blue Hose, 1 Pair AWG 20 Tinned Copper - Stranded, Polyolefin (PO, PE, PP) insulation, Foil + Braid(s) shielding, LSZH / FRNC jacket , Steel Wire Armor
Specifications
Specifications
Product Overview
| Suitable Applications | Twinaxial instrumentation and computer cable; For data transmission applications; Suitable for outdoor application (sunlight resistant) and direct burial |
|---|
Physical Characteristics (Overall)
Conductor
| AWG | Stranding | Material | No. of Pairs |
|---|
| 20 | 7x28 | TC - Tinned Copper | 1 |
| Conductor Count | 2 |
|---|
| Total Number of Pairs | 1 |
|---|
Insulation
| Material | Nominal Diameter | Diameter +/- Tolerance |
|---|
| PE - Polyethylene | 1.96 mm | 0.05 mm |
Color Chart
| Number | Color |
|---|
| Pair 1 | Clear & Blue |
Inner Shield
| Type | Material | Material Trade Name | Coverage [%] | Drainwire Material | Drainwire AWG |
|---|
| Tape | Bi-Laminate (Alum+Poly) | Beldfoil® (Z-Fold®) | | TC - Tinned Copper | AWG20/7 |
| Braid | Tinned Copper (TC) | | 55% | | |
Inner Jacket
| Material | Color | Nominal Diameter | Nominal Wall Thickness |
|---|
| LSZH - Low Smoke Zero Halogen (Flame Retardant) | Blue (RAL 5012) | 6.35 mm | 0.89 mm |
Outer Jacket
| Material | Nominal Diameter | Nominal Wall Thickness |
|---|
| LSZH - Low Smoke Zero Halogen (Flame Retardant) | 10.75 mm | 1.3 mm |
Construction and Dimensions
Cabling
| Description | Filler |
|---|
| 1 pair and 2 fillers twisted to cable core | Polyethylene (2x) (Clear, 1.32 mm) |
Armor
| Type of Armor | Material | Thickness of Armoring Wires | Coverage Percentage |
|---|
| Steel Wire Armoring | Galvanized steel wire | 0.9 mm | Min. 95% |
Electrical Characteristics
Conductor DCR
| Max. DCR Unbalance | Nominal Conductor DCR | Nominal Outer Shield DCR |
|---|
| 2.53 % | 31.2 Ohm/km | 13.5 Ohm/km |
Capacitance
| Nom. Capacitance Conductor to Conductor | Nom. Capacitance Conductor to Shield |
|---|
| 64.6 pF/m | 118.1 pF/m |
Impedance
| Frequency [MHz] | Nominal Characteristic Impedance |
|---|
| N/A | 78 Ohm |
High Frequency (Nominal/Typical)
| Frequency [MHz] | Nom. Insertion Loss |
|---|
| 1 MHz | 1.97 dB/100m |
| 10 MHz | 6.89 dB/100m |
| 50 MHz | 11.81 dB/100m |
| 100 MHz | 24.61 dB/100m |
| 200 MHz | 36.09 dB/100m |
| 400 MHz | 52.49 dB/100m |
Delay
| Nominal Velocity of Propagation (VP) [%] |
|---|
| 66% |
Voltage
Temperature Range
| Installation Temperature Range | -15°C To +80°C |
|---|
| Storage Temperature Range | -45°C To +80°C |
|---|
| Operating Temp Range (Flexible Install) | -15°C To +80°C |
|---|
| Operating Temp Range (Fixed Install) | -45°C To +80°C |
|---|
Mechanical Characteristics
| Oil Resistance | IEC 60811-404 |
|---|
| Min. Bend Radius During Installation | 161.25 mm |
|---|
Standards
| CENELEC Compliance | EN 50290-2-20 |
|---|
Applicable Environmental and Other Programs
| Environmental Space | Outdoor |
|---|
Suitability
| Suitability - Sunlight Resistance | Yes |
|---|
Flammability, LS0H, Toxicity Testing
| IEC Flammability | IEC 60332-3-24 |
|---|
| IEC 60754-1 - Halogen Amount | Zero |
|---|
| IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity | 2.5 µS/mm |
|---|
| IEC 60754-2 - Halogen Acid Gas Amount - Min. pH | 4.3 |
|---|
| IEC 61034-2 - Smoke Density Min. Transmittance | 60% |
|---|
History
| Update and Revision | Revision Number: 0.220 Revision Date: 02-23-2023 |
|---|
Documentation
Product Bulletins
Catalogs
Guides
Line Cards
Data Sheets