Blue Hose, 1 Pair AWG 20 Tinned Copper - Stranded, Polyolefin (PO, PE, PP) insulation, Foil + Braid(s) shielding, LSZH / FRNC jacket , Steel Wire Armor
Specifications
Specifications
Product Overview
Suitable Applications | Twinaxial instrumentation and computer cable; For data transmission applications; Suitable for outdoor application (sunlight resistant) and direct burial |
---|
Physical Characteristics (Overall)
Conductor
AWG | Stranding | Material | No. of Pairs |
---|
20 | 7x28 | TC - Tinned Copper | 1 |
Conductor Count | 2 |
---|
Total Number of Pairs | 1 |
---|
Insulation
Material | Nominal Diameter | Diameter +/- Tolerance |
---|
PE - Polyethylene | 1.96 mm | 0.05 mm |
Color Chart
Number | Color |
---|
Pair 1 | Clear & Blue |
Inner Shield
Type | Material | Material Trade Name | Coverage [%] | Drainwire Material | Drainwire AWG |
---|
Tape | Bi-Laminate (Alum+Poly) | Beldfoil® (Z-Fold®) | | TC - Tinned Copper | AWG20/7 |
Braid | Tinned Copper (TC) | | 55% | | |
Inner Jacket
Material | Color | Nominal Diameter | Nominal Wall Thickness |
---|
LSZH - Low Smoke Zero Halogen (Flame Retardant) | Blue (RAL 5012) | 6.35 mm | 0.89 mm |
Outer Jacket
Material | Nominal Diameter | Nominal Wall Thickness |
---|
LSZH - Low Smoke Zero Halogen (Flame Retardant) | 10.75 mm | 1.3 mm |
Construction and Dimensions
Cabling
Description | Filler |
---|
1 pair and 2 fillers twisted to cable core | Polyethylene (2x) (Clear, 1.32 mm) |
Armor
Type of Armor | Material | Thickness of Armoring Wires | Coverage Percentage |
---|
Steel Wire Armoring | Galvanized steel wire | 0.9 mm | Min. 95% |
Electrical Characteristics
Conductor DCR
Max. DCR Unbalance | Nominal Conductor DCR | Nominal Outer Shield DCR |
---|
2.53 % | 31.2 Ohm/km | 13.5 Ohm/km |
Capacitance
Nom. Capacitance Conductor to Conductor | Nom. Capacitance Conductor to Shield |
---|
64.6 pF/m | 118.1 pF/m |
Impedance
Frequency [MHz] | Nominal Characteristic Impedance |
---|
N/A | 78 Ohm |
High Frequency (Nominal/Typical)
Frequency [MHz] | Nom. Insertion Loss |
---|
1 MHz | 1.97 dB/100m |
10 MHz | 6.89 dB/100m |
50 MHz | 11.81 dB/100m |
100 MHz | 24.61 dB/100m |
200 MHz | 36.09 dB/100m |
400 MHz | 52.49 dB/100m |
Delay
Nominal Velocity of Propagation (VP) [%] |
---|
66% |
Voltage
Temperature Range
Installation Temperature Range | -15°C To +80°C |
---|
Storage Temperature Range | -45°C To +80°C |
---|
Operating Temp Range (Flexible Install) | -15°C To +80°C |
---|
Operating Temp Range (Fixed Install) | -45°C To +80°C |
---|
Mechanical Characteristics
Oil Resistance | IEC 60811-404 |
---|
Min. Bend Radius During Installation | 161.25 mm |
---|
Standards
CENELEC Compliance | EN 50290-2-20 |
---|
Applicable Environmental and Other Programs
Environmental Space | Outdoor |
---|
Suitability
Suitability - Sunlight Resistance | Yes |
---|
Flammability, LS0H, Toxicity Testing
IEC Flammability | IEC 60332-3-24 |
---|
IEC 60754-1 - Halogen Amount | Zero |
---|
IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity | 2.5 µS/mm |
---|
IEC 60754-2 - Halogen Acid Gas Amount - Min. pH | 4.3 |
---|
IEC 61034-2 - Smoke Density Min. Transmittance | 60% |
---|
History
Update and Revision | Revision Number: 0.220 Revision Date: 02-23-2023 |
---|
Documentation
Product Bulletins
Catalogs
Guides
Line Cards
Data Sheets