5-Pair, 24 AWG stranded (7x32) TC conductors, PE insulation, twisted pairs, overall Beldfoil shield (100% coverage), 24 AWG stranded TC drain Wire, LSZH jacket, Flame resistance IEC 60332-3C
Specifications
Specifications
Product Overview
| Suitable Applications | Instrumentation and computer cable; For EIA RS-232 data transmission applications |
|---|
Physical Characteristics (Overall)
Conductor
| AWG | Stranding | Material | No. of Pairs |
|---|
| 24 | 7x32 | TC - Tinned Copper | 5 |
Insulation
| Material | Nominal Diameter | Diameter +/- Tolerance |
|---|
| PE - Polyethylene | 1.12 mm | 0.05 mm |
Color Chart
| Number | Color |
|---|
| Pair 1 | Black & Red |
| Pair 2 | Black & White |
| Pair 3 | Black & Green |
| Pair 4 | Black & Blue |
| Pair 5 | Black & Yellow |
Outer Shield
| Type | Material | Material Trade Name | Thickness of Foil | Drainwire Material | Drainwire AWG |
|---|
| Tape | Bi-Laminate (Alum+Poly) | Beldfoil® | 9 / 23 µm | TC - Tinned Copper | AWG24/7 |
Outer Jacket
| Material | Nominal Diameter | Nominal Wall Thickness |
|---|
| LSZH - Low Smoke Zero Halogen (Flame Retardant) | 7.5 mm | 0.9 mm |
Construction and Dimensions
Cabling
| Description | Filler |
|---|
| 1 center filler and 5 pairs twisted to cable core | Polypropylene (White, 1.90 mm) |
Electrical Characteristics
Conductor DCR
| Nominal Conductor DCR | Nominal Outer Shield DCR |
|---|
| 78.7 Ohm/km | 55.8 Ohm/km |
Capacitance
| Nom. Capacitance Conductor to Conductor | Nom. Capacitance Conductor to Other Conductor to Shield |
|---|
| 59.0 pF/m | 84.0 pF/m |
Impedance
Current
| Element | Max. Recommended Current [A] |
|---|
| Conductor(s) | 1.5 Amps per Conductor |
Voltage
Temperature Range
| Installation Temperature Range | -15°C To +80°C |
|---|
| Storage Temperature Range | -45°C To +80°C |
|---|
| Operating Temp Range (Flexible Install) | -15°C To +80°C |
|---|
| Operating Temp Range (Fixed Install) | -45°C To +80°C |
|---|
Mechanical Characteristics
| Oil Resistance | IEC 60811-404 |
|---|
| Max. Pull Tension | 250 N |
|---|
| Min. Bend Radius During Installation | 75 mm |
|---|
Standards
| CPR Euroclass | Dca-s2,d2,a1 |
|---|
| CENELEC Compliance | EN 50290-2-20 |
|---|
Applicable Environmental and Other Programs
| Environmental Space | Indoor - Euroclass Dca |
|---|
Suitability
| Suitability - Sunlight Resistance | Yes |
|---|
Flammability, LS0H, Toxicity Testing
| IEC Flammability | IEC 60332-1-2, IEC 60332-3-24 |
|---|
| IEC 60754-1 - Halogen Amount | Zero |
|---|
| IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity | 2.5 µS/mm |
|---|
| IEC 60754-2 - Halogen Acid Gas Amount - Min. pH | 4.3 |
|---|
| IEC 61034-2 - Smoke Density Min. Transmittance | 60% |
|---|
History
| Update and Revision | Revision Number: 0.216 Revision Date: 12-19-2022 |
|---|
Documentation
Product Bulletins
Data Sheets