Belden

9536NH - RS-232, 6C #24 Str TC, PO ins, OS, LSZH Jkt, 300V

(No reviews yet) Write a Review
SKU:
9536NH
Shipping:
Calculated at Checkout

Description

24 AWG stranded (7x32) tinned copper conductors, 6 conductors cabled, PE insulation, overall Beldfoil® shield (100% coverage), 24 AWG stranded tinned copper drain wire, LSZH jacket, Flame resistance IEC 60332-3-24

Specifications

Specifications

Product Overview

Suitable ApplicationsInstrumentation and computer cable; For EIA RS-232 data transmission applications

Physical Characteristics (Overall)

Conductor

AWGStrandingMaterialNo. of Conductors
247x32TC - Tinned Copper6
Conductor Count6

Insulation

MaterialNominal DiameterDiameter +/- Tolerance
PE - Polyethylene1.12 mm0.05 mm

Color Chart

NumberColor
Wire 1Black
Wire 2White
Wire 3Red
Wire 4Green
Wire 5Brown
Wire 6Blue

Outer Shield

TypeMaterialMaterial Trade NameThickness of FoilDrainwire MaterialDrainwire AWG
TapeBi-Laminate (Alum+Poly)Beldfoil®9 / 12 µmTC - Tinned CopperAWG24/7

Outer Jacket

MaterialNominal DiameterNominal Wall Thickness
LSZH - Low Smoke Zero Halogen (Flame Retardant)5.5 mm0.9 mm

Construction and Dimensions

Cabling

DescriptionFiller
1 center filler and 6 wires twisted to cable coreCotton (White)

Electrical Characteristics

Conductor DCR

Nominal Conductor DCRNominal Outer Shield DCR
82 Ohm/km59.1 Ohm/km

Capacitance

Nom. Capacitance Conductor to ConductorNom. Capacitance Conductor to Other Conductor to Shield
108.3 pF/m213.3 pF/m

Impedance

Frequency [MHz]Nominal Characteristic Impedance
N/A75 Ohm

Current

ElementMax. Recommended Current [A]
Conductor(s)1.75 Amps per Conductor

Voltage

Voltage Rating [V]
300 V

Temperature Range

Installation Temperature Range-15°C To +80°C
Storage Temperature Range-45°C To +80°C
Operating Temp Range (Flexible Install)-15°C To +80°C
Operating Temp Range (Fixed Install)-45°C To +80°C

Mechanical Characteristics

Oil ResistanceIEC 60811-404
Max. Pull Tension150 N
Min. Bend Radius During Installation55 mm

Standards

CPR EuroclassDca-s2,d1,a1
CENELEC ComplianceEN 50290-2-20

Applicable Environmental and Other Programs

Environmental SpaceIndoor - Euroclass Dca

Suitability

Suitability - IndoorYes
Suitability - Non-HalogenatedYes
Suitability - Sunlight ResistanceYes

Flammability, LS0H, Toxicity Testing

IEC FlammabilityIEC 60332-1-2, IEC 60332-3-24
IEC 60754-1 - Halogen AmountZero
IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity2.5 µS/mm
IEC 60754-2 - Halogen Acid Gas Amount - Min. pH4.3
IEC 61034-2 - Smoke Density Min. Transmittance60%

History

Update and RevisionRevision Number: 0.215 Revision Date: 12-19-2022
View AllClose

Additional Information

Variant_Options:
Item #|Color|Put-Up Type|Length|EAN
Variant_Options 9536NH.00100:
9536NH.00100|Chrome|Reel|100 m|8719605176936
Variant_Options 9536NH.00305:
9536NH.00305|Chrome|Reel|305 m|8719605021939
Variant_Options 9536NH.00500:
9536NH.00500|Chrome|Reel|500 m|8719605021946
Variant_Options 9536NH.001000:
9536NH.001000|Chrome|Reel|1,000 m|8719605021922
View AllClose