24 AWG stranded (7x32) tinned copper conductors, 15 conductors cabled, PE insulation, overall Beldfoil® shield (100% coverage), 24 AWG stranded tinned copper drain wire, LSZH jacket, Flame resistance IEC 60332-3-24
Specifications
Specifications
Product Overview
| Suitable Applications | Instrumentation and computer cable; For EIA RS-232 data transmission applications |
|---|
Physical Characteristics (Overall)
Conductor
| AWG | Stranding | Material | No. of Conductors |
|---|
| 24 | 7x32 | TC - Tinned Copper | 15 |
Insulation
| Material | Nominal Diameter | Diameter +/- Tolerance |
|---|
| PE - Polyethylene | 1.12 mm | 0.05 mm |
Color Chart
| Number | Color |
|---|
| Wire 1 (central) | Black |
| Wire 2 (central) | White |
| Wire 3 (central) | Red |
| Wire 4 (central) | Green |
| Wire 5 | Orange |
| Wire 6 | Blue |
| Wire 7 | Black/White |
| Wire 8 | Black/Red |
| Wire 9 | Black/Green |
| Wire 10 | Black/Orange |
| Wire 11 | Black/Blue |
| Wire 12 | Black/White |
| Wire 13 | White/Red |
| Wire 14 | White/Green |
| Wire 15 | White/Blue |
Outer Shield
| Type | Material | Material Trade Name | Thickness of Foil | Drainwire Material | Drainwire AWG |
|---|
| Tape | Bi-Laminate (Alum+Poly) | Beldfoil® | 9 / 23 µm | TC - Tinned Copper | AWG24/7 |
Outer Jacket
| Material | Nominal Diameter | Min. Wall Thickness | Min. Average Wall Thickness |
|---|
| LSZH - Low Smoke Zero Halogen (Flame Retardant) | 7.4 mm | 0.65 mm | 0.80 mm |
Construction and Dimensions
Cabling
| Description | Filler |
|---|
| 1 center filler and 15 wires twisted to cable core | Cotton (White) |
Electrical Characteristics
Conductor DCR
| Nominal Conductor DCR | Nominal Outer Shield DCR |
|---|
| 82 Ohm/km | 59.1 Ohm/km |
Capacitance
| Nom. Capacitance Conductor to Conductor | Nom. Capacitance Conductor to Other Conductor to Shield |
|---|
| 98 pF/m | 180 pF/m |
Impedance
| Frequency [MHz] | Nominal Characteristic Impedance |
|---|
| N/A | 75 Ohm |
Current
| Element | Max. Recommended Current [A] |
|---|
| Conductor(s) | 1.75 Amps per Conductor |
Voltage
Temperature Range
| Installation Temperature Range | -15°C To +80°C |
|---|
| Storage Temperature Range | -45°C To +80°C |
|---|
| Operating Temp Range (Flexible Install) | -15°C To +80°C |
|---|
| Operating Temp Range (Fixed Install) | -45°C To +80°C |
|---|
Mechanical Characteristics
| Oil Resistance | IEC 60811-404 |
|---|
| Max. Pull Tension | 360 N |
|---|
| Min. Bend Radius During Installation | 74 mm |
|---|
Standards
| CPR Euroclass | Dca-s2,d1,a1 |
|---|
| CENELEC Compliance | EN 50290-2-20 |
|---|
Applicable Environmental and Other Programs
| Environmental Space | Indoor - Euroclass Dca |
|---|
Flammability, LS0H, Toxicity Testing
| IEC Flammability | IEC 60332-1-2, IEC 60332-3-24 |
|---|
| IEC 60754-1 - Halogen Amount | Zero |
|---|
| IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity | 2.5 µS/mm |
|---|
| IEC 60754-2 - Halogen Acid Gas Amount - Min. pH | 4.3 |
|---|
| IEC 61034-2 - Smoke Density Min. Transmittance | 60% |
|---|
History
| Update and Revision | Revision Number: 0.206 Revision Date: 12-19-2022 |
|---|
Documentation
Product Bulletins
Data Sheets