Computer EIA RS-232 Cable, 24 AWG stranded (7x32) tinned copper conductors, FRNC insulation, overall Beldfoil® shield (100% coverage), 24 AWG stranded tinned copper drain wire, FRNC jacket.
Specifications
Specifications
Product Overview
| Suitable Applications | RS-232 Applications; Computer Communications; Low Voltage Analog Signals (4-20mA, 0-10V, ...); Low Voltage Digital Control (24V, …); Line Level Audio; Panel Wiring |
|---|
Construction Details
Conductor
| Element | Number of Element | Size | Stranding | Material |
|---|
| Conductor(s) | 20 | 24 AWG | 7x32 | TC - Tinned Copper |
Insulation
| Element | Material | Nom. Insulation Diameter | Color Code |
|---|
| Conductor(s) | LSZH - Low Smoke Zero Halogen (Flame Retardant) | 1.25 mm (0.0492 in) | red, black, white, Green, brown, blue, orange, yellow, purple, gray, pink, turquoise, Black/White, Red/White, Green/White, Orange/White, Blue/White, Brown/White, Yellow/White, Gray/White |
Outer Shield
| Shield Type | Material | Coverage | Drainwire Type |
|---|
| Tape | Bi-Laminate (Alum+Poly) | 100% | 24 AWG (7x32) TC |
Outer Jacket
| Material | Nom. Thickness | Nom. Diameter |
|---|
| LSZH - Low Smoke Zero Halogen (Flame Retardant) | 1.4 mm (0.055 in) | 9.4 mm (0.37 in) |
| Overall Cable Diameter (Nominal) | 9.40 mm (0.370 in) |
|---|
Electrical Characteristics
Electricals
| Element | Nom. Conductor DCR | Nom. Capacitance Cond-to-Cond | Nom. Capacitance Cond-to-Other (Conds + Shield) | Max. Current |
|---|
| Conductor(s) | 82 Ohm/km (25 Ohm/1000ft) | 108 pF/m (32.9 pF/ft) | 213 pF/m (64.9 pF/ft) | 1.3 Amps per Conductor at 25ºC |
Mechanical Characteristics
Temperature
| Operating | Installation | Storage |
|---|
| -20°C to +70°C | -20°C To +70°C | -30°C To +70°C |
Bend Radius
| Stationary Min. | Installation Min. |
|---|
| 47 mm (1.9 in) | 94 mm (3.7 in) |
| Max. Pull Tension | 175 N (39.3 lbf) |
|---|
Standards and Compliance
| Environmental Suitability | Indoor - Euroclass Cca, Indoor |
|---|
| Flammability / Reaction to Fire | IEC 60332-1-2 |
|---|
| CPR Compliance | CPR Euroclass: Cca-s1,d1,a1 |
|---|
| CENELEC Compliance | EN 50290-2-27 |
|---|
| European Halogen Free Standards | IEC 62821-1 Halogen Free Compliance = Yes, IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity = 2.5 µS/mm, IEC 60754-2 - Halogen Acid Gas Amount - Min. pH = 4.3 |
|---|
| UK Regulation Compliance | UKCA Mark |
|---|
History
| Update and Revision | Revision Number: 0.4 Revision Date: 05-30-2023 |
|---|
Documentation
Product Bulletins
Compliance Documentation
Data Sheets