100 Ohm Twinax, 20 AWG stranded (7x28) .037" one tinned/ one bare copper conductors, polyethylene insulation, Duofoil® + tinned copper braid shield (95% coverage), high-density polyethylene jacket.
Specifications
Specifications
Physical Characteristics (Overall)
Conductor
AWG | Stranding | Material | Construction n x D | No. of Conductors |
---|
20 | 7x28 | TC - Tinned Copper | Stranded | 1 |
20 | 7x28 | BC - Bare Copper | Stranded | 1 |
Insulation
Material | Nominal Wall Thickness |
---|
PE - Polyethylene | 0.024 in |
Color Chart
Number | Color |
---|
1 | Natural & Natural |
Inner Jacket
Material | Nominal Diameter | Nominal Wall Thickness |
---|
PE - Polyethylene | 0.236 in | 0.035 in |
Outer Shield
Type | Layer | Material | Material Trade Name | Coverage [%] |
---|
Tape | 1 | Tri-Laminate (Alum+Poly+Alum) | Duofoil® | 100% |
Braid | 2 | Tinned Copper (TC) | | 95% |
Table Notes | Polyethylene Grease |
---|
Outer Jacket
Material | Nominal Diameter | Nominal Wall Thickness |
---|
PE - Polyethylene | 0.33 in | 0.034 in |
Electrical Characteristics
Conductor DCR
Nominal Conductor DCR | Nominal Outer Shield DCR | Outer Conductor DCR |
---|
9.5 Ohm/1000ft | 2 Ohm/1000ft | 2 Ohm/1000ft |
Capacitance
Nom. Capacitance Conductor to Conductor | Nom. Capacitance Conductor to Other Conductor to Shield | Nom. Capacitance Conductor to Shield |
---|
14.5 pF/ft | 23 pF/ft | 14.5 pF/ft |
Inductance
Nominal Inductance |
---|
0.155 µH/ft |
Impedance
Nominal Characteristic Impedance |
---|
100 Ohm |
High Frequency (Nominal/Typical)
Frequency [MHz] | Nom. Insertion Loss |
---|
1 MHz | 0.4 dB/100ft |
10 MHz | 1.1 dB/100ft |
50 MHz | 2.5 dB/100ft |
100 MHz | 4.1 dB/100ft |
200 MHz | 6.4 dB/100ft |
400 MHz | 10.2 dB/100ft |
Delay
Max. Delay Skew | Nominal Delay | Nominal Velocity of Propagation (VP) [%] |
---|
66 ns/100m | 1.54 ns/ft | 66% |
High Frequency
Frequency [MHz] |
---|
1 MHz |
10 MHz |
50 MHz |
100 MHz |
200 MHz |
400 MHz |
Voltage
Non-UL Voltage Rating |
---|
600 V RMS |
Electrical Characteristics Notes | Capacitance conductor to shield: 23.0 pF/ft |
---|
Temperature Range
Operating Temperature Range | -55°C To +80°C |
---|
Mechanical Characteristics
Bulk Cable Weight | 62 lbs/1000ft |
---|
Max. Pull Tension | 115 lbs |
---|
Min. Bend Radius/Minor Axis | 3.5 in |
---|
Standards
Applicable Environmental and Other Programs
EU Directive 2000/53/EC (ELV) | Yes |
---|
EU Directive 2003/11/EC (BFR) | Yes |
---|
EU Directive 2011/65/EU (RoHS 2) | Yes |
---|
EU Directive 2012/19/EU (WEEE) | Yes |
---|
EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
---|
EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
---|
EU CE Mark | Yes |
---|
MII Order #39 (China RoHS) | Yes |
---|
Suitability
Plenum/Non-Plenum
Related Part Numbers
Footnote | C - CRATE REEL PUT-UP. |
---|
Product Notes
Notes | Polyethylene flooding grease applied over outer shield. |
---|
History
Update and Revision | Revision Number: 0.344 Revision Date: 05-05-2023 |
---|
Documentation
Product Bulletins
Data Sheets