100 Ohm Twinax, 20 AWG stranded (7x28) .037" one tinned/ one bare copper conductors, polyethylene insulation, Duofoil® + tinned copper braid shield (95% coverage), high-density polyethylene jacket.
Specifications
Specifications
Physical Characteristics (Overall)
Conductor
| AWG | Stranding | Material | Construction n x D | No. of Conductors |
|---|
| 20 | 7x28 | TC - Tinned Copper | Stranded | 1 |
| 20 | 7x28 | BC - Bare Copper | Stranded | 1 |
Insulation
| Material | Nominal Wall Thickness |
|---|
| PE - Polyethylene | 0.024 in |
Color Chart
| Number | Color |
|---|
| 1 | Natural & Natural |
Inner Jacket
| Material | Nominal Diameter | Nominal Wall Thickness |
|---|
| PE - Polyethylene | 0.236 in | 0.035 in |
Outer Shield
| Type | Layer | Material | Material Trade Name | Coverage [%] |
|---|
| Tape | 1 | Tri-Laminate (Alum+Poly+Alum) | Duofoil® | 100% |
| Braid | 2 | Tinned Copper (TC) | | 95% |
| Table Notes | Polyethylene Grease |
|---|
Outer Jacket
| Material | Nominal Diameter | Nominal Wall Thickness |
|---|
| PE - Polyethylene | 0.33 in | 0.034 in |
Electrical Characteristics
Conductor DCR
| Nominal Conductor DCR | Nominal Outer Shield DCR | Outer Conductor DCR |
|---|
| 9.5 Ohm/1000ft | 2 Ohm/1000ft | 2 Ohm/1000ft |
Capacitance
| Nom. Capacitance Conductor to Conductor | Nom. Capacitance Conductor to Other Conductor to Shield | Nom. Capacitance Conductor to Shield |
|---|
| 14.5 pF/ft | 23 pF/ft | 14.5 pF/ft |
Inductance
| Nominal Inductance |
|---|
| 0.155 µH/ft |
Impedance
| Nominal Characteristic Impedance |
|---|
| 100 Ohm |
High Frequency (Nominal/Typical)
| Frequency [MHz] | Nom. Insertion Loss |
|---|
| 1 MHz | 0.4 dB/100ft |
| 10 MHz | 1.1 dB/100ft |
| 50 MHz | 2.5 dB/100ft |
| 100 MHz | 4.1 dB/100ft |
| 200 MHz | 6.4 dB/100ft |
| 400 MHz | 10.2 dB/100ft |
Delay
| Max. Delay Skew | Nominal Delay | Nominal Velocity of Propagation (VP) [%] |
|---|
| 66 ns/100m | 1.54 ns/ft | 66% |
High Frequency
| Frequency [MHz] |
|---|
| 1 MHz |
| 10 MHz |
| 50 MHz |
| 100 MHz |
| 200 MHz |
| 400 MHz |
Voltage
| Non-UL Voltage Rating |
|---|
| 600 V RMS |
| Electrical Characteristics Notes | Capacitance conductor to shield: 23.0 pF/ft |
|---|
Temperature Range
| Operating Temperature Range | -55°C To +80°C |
|---|
Mechanical Characteristics
| Bulk Cable Weight | 62 lbs/1000ft |
|---|
| Max. Pull Tension | 115 lbs |
|---|
| Min. Bend Radius/Minor Axis | 3.5 in |
|---|
Standards
Applicable Environmental and Other Programs
| EU Directive 2000/53/EC (ELV) | Yes |
|---|
| EU Directive 2003/11/EC (BFR) | Yes |
|---|
| EU Directive 2011/65/EU (RoHS 2) | Yes |
|---|
| EU Directive 2012/19/EU (WEEE) | Yes |
|---|
| EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
|---|
| EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
|---|
| EU CE Mark | Yes |
|---|
| MII Order #39 (China RoHS) | Yes |
|---|
Suitability
Plenum/Non-Plenum
Related Part Numbers
| Footnote | C - CRATE REEL PUT-UP. |
|---|
Product Notes
| Notes | Polyethylene flooding grease applied over outer shield. |
|---|
History
| Update and Revision | Revision Number: 0.344 Revision Date: 05-05-2023 |
|---|
Documentation
Product Bulletins
Data Sheets