2-Pair, 24 AWG stranded (7x32) TC conductors, polyethylene insulation, twisted pairs, overall Beldfoil® (100% coverage) + TC braid shield (65% coverage), 24 AWG stranded TC drain wire, LSZH jacket, Flame resistance IEC 60332-3C
Specifications
Specifications
Product Overview
Suitable Applications | RS-232 extended distance applications; RS-422 applications; computer communications; low voltage analog signals (4-20ma, 0-10v, ...); low voltage digital control (24v, …); line level audio; panel wiring |
---|
Physical Characteristics (Overall)
Conductor
AWG | Stranding | Material | No. of Pairs |
---|
24 | 7x32 | TC - Tinned Copper | 2 |
Insulation
Material | Nominal Diameter | Diameter +/- Tolerance |
---|
PE - Polyethylene | 1.37 mm | 0.05 mm |
Color Chart
Number | Color |
---|
Pair 1 | White/Blue & Blue/White |
Pair 2 | White/Orange & Orange/White |
Outer Shield
Type | Material | Material Trade Name | Coverage [%] | Thickness of Foil | Drainwire Material | Drainwire AWG |
---|
Tape | Bi-Laminate (Alum+Poly) | Beldfoil® | 65% | 9 / 23 µm | TC - Tinned Copper | AWG24/7 |
Braid | Tinned Copper (TC) | | 65% | | | |
Outer Jacket
Material | Nominal Diameter | Nominal Wall Thickness |
---|
LSZH - Low Smoke Zero Halogen (Flame Retardant) | 7.1 mm | 0.9 mm |
Construction and Dimensions
Cabling
Description | Filler |
---|
2 pairs and 2 fillers twisted to cable core | Polypropylene (2x) (White, 2.20 mm) |
Electrical Characteristics
Conductor DCR
Nominal Conductor DCR | Nominal Outer Shield DCR |
---|
78.7 Ohm/km | 14.3 Ohm/km |
Capacitance
Nom. Capacitance Conductor to Conductor | Nom. Capacitance Conductor to Other Conductor to Shield |
---|
50.9 pF/m | 90.2 pF/m |
Impedance
Frequency [MHz] | Nominal Characteristic Impedance |
---|
1 | 100 Ohm |
Delay
Nominal Delay | Nominal Velocity of Propagation (VP) [%] |
---|
520 ns/ft | 66% |
Current
Element | Max. Recommended Current [A] |
---|
Conductor(s) | 2.1 Amps per Conductor |
Voltage
Temperature Range
Installation Temperature Range | -15°C To +80°C |
---|
Storage Temperature Range | -45°C To +80°C |
---|
Operating Temp Range (Flexible Install) | -15°C To +80°C |
---|
Operating Temp Range (Fixed Install) | -45°C To +80°C |
---|
Mechanical Characteristics
Oil Resistance | IEC 60811-404 |
---|
Max. Pull Tension | 260 N |
---|
Min. Bend Radius During Installation | 71 mm |
---|
Standards
CPR Euroclass | Dca-s2,d1,a1 |
---|
CENELEC Compliance | EN 50290-2-20 |
---|
Applicable Environmental and Other Programs
Environmental Space | Indoor - Euroclass Dca |
---|
Suitability
Suitability - Sunlight Resistance | Yes |
---|
Flammability, LS0H, Toxicity Testing
IEC Flammability | IEC 60332-1-2, IEC 60332-3-24 |
---|
IEC 60754-1 - Halogen Amount | Zero |
---|
IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity | 2.5 µS/mm |
---|
IEC 60754-2 - Halogen Acid Gas Amount - Min. pH | 4.3 |
---|
IEC 61034-2 - Smoke Density Min. Transmittance | 60% |
---|
History
Update and Revision | Revision Number: 0.246 Revision Date: 12-19-2022 |
---|
Documentation
Product Bulletins
Data Sheets