RS-485, 4 Pair AWG 24 Tinned Copper - Stranded, Polyolefin (PO, PE, PP) insulation, Foil + Braid(s) shielding, LSZH / FRNC jacket , 300V, SWA
Specifications
Specifications
Product Overview
| Suitable Applications | RS-485, POS; Computer communications; Low Voltage Analog Signals (4-20ma, 0-10v, ...); Low Voltage Digital Control (24v, …); Line Level Audio; Panel Wiring; serial communication (RS-485 standard) comprising of PLCs, VFDs, HMIs, motors, RTU, SCADA, etc. within noisy environments over long distance, etc. |
|---|
Physical Characteristics (Overall)
Conductor
| AWG | Stranding | Material | No. of Pairs |
|---|
| 24 | 7x32 | TC - Tinned Copper | 4 |
| Conductor Count | 8 |
|---|
| Total Number of Pairs | 4 |
|---|
Insulation
| Material | Nominal Diameter | Diameter +/- Tolerance |
|---|
| PE - Polyethylene | 1.73 mm | 0.05 mm |
Color Chart
| Number | Color |
|---|
| Pair 1 | White/Blue & Blue/White |
| Pair 2 | White/Orange & Orange/White |
| Pair 3 | White/Green & Green/White |
| Pair 4 | White/Brown & Brown/White |
Inner Jacket
| Material | Color | Nominal Diameter | Nominal Wall Thickness |
|---|
| LSZH - Low Smoke Zero Halogen (Flame Retardant) | Chrome (RAL 7037) | 9.9 mm | 0.89 mm |
Outer Shield
| Type | Material | Material Trade Name | Coverage [%] | Drainwire Material | Drainwire AWG |
|---|
| Tape | | Beldfoil® (Z-Fold®) | 100% | TC - Tinned Copper | AWG 24/7 |
| Braid | Tinned Copper (TC) | | 90% | | |
Outer Jacket
| Material | Nominal Diameter | Nominal Wall Thickness |
|---|
| LSZH - Low Smoke Zero Halogen (Flame Retardant) | 15.1 mm | 1.35 mm |
Construction and Dimensions
Cabling
| Description |
|---|
| 4 pairs twisted to cable core |
Armor
| Type of Armor | Material | Thickness of Armoring Wires | Coverage Percentage |
|---|
| Steel Wire Armoring | Galvanized steel wire | 1.25 mm | Min. 95% |
Electrical Characteristics
Conductor DCR
| Nominal Conductor DCR | Nominal Outer Shield DCR |
|---|
| 78.7 Ohm/km | 6.9 Ohm/km |
Capacitance
| Nom. Capacitance Conductor to Conductor | Nom. Capacitance Conductor to Other Conductor to Shield |
|---|
| 42 pF/m | 75.5 pF/m |
Impedance
| Frequency [MHz] | Nominal Characteristic Impedance |
|---|
| 1 MHz | 120 Ohm |
High Frequency (Nominal/Typical)
| Frequency [MHz] | Nom. Insertion Loss |
|---|
| 1 MHz | 1.97 dB/100m |
Delay
| Nominal Delay | Nominal Velocity of Propagation (VP) [%] |
|---|
| 520 ns/ft | 66% |
Current
| Element | Max. Recommended Current [A] |
|---|
| Conductor(s) | 2.1 Amps per Conductor |
Voltage
Temperature Range
| Installation Temperature Range | -15°C To +80°C |
|---|
| Storage Temperature Range | -45°C To +80°C |
|---|
| Operating Temp Range (Flexible Install) | -15°C To +80°C |
|---|
| Operating Temp Range (Fixed Install) | -45°C To +80°C |
|---|
Mechanical Characteristics
| Oil Resistance | IEC 60811-404 |
|---|
| Max. Pull Tension | 500 N |
|---|
| Min. Bend Radius During Installation | 151 mm |
|---|
Standards
| CENELEC Compliance | EN 50290-2-20 |
|---|
Applicable Environmental and Other Programs
| Environmental Space | Indoor/Outdoor |
|---|
| EU CE Mark | Yes |
|---|
Suitability
| Suitability - Indoor | Yes |
|---|
| Suitability - Non-Halogenated | Yes |
|---|
| Suitability - Oil Resistance | Yes |
|---|
| Suitability - Outdoor | Yes |
|---|
| Suitability - Sunlight Resistance | Yes |
|---|
Flammability, LS0H, Toxicity Testing
| IEC Flammability | IEC 60332-3-24 |
|---|
| IEC 60754-1 - Halogen Amount | Zero |
|---|
| IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity | 2.5 µS/mm |
|---|
| IEC 60754-2 - Halogen Acid Gas Amount - Min. pH | 4.3 |
|---|
| IEC 61034-2 - Smoke Density Min. Transmittance | 60% |
|---|
History
| Update and Revision | Revision Number: 0.219 Revision Date: 11-09-2022 |
|---|
Documentation
Product Bulletins
Catalogs
Guides
Line Cards
Data Sheets