93 Ohm Coax MIL-DTL-17 QPL, M17/30-RG062, 22 AWG solid .025" bare copper-covered steel conductor, semi-solid polyethylene insulation, bare copper braid shield (95% coverage), non-contaminating PVC jacket.
Specifications
Specifications
Product Overview
Suitable Applications | RF, Antenna, Mil Spec |
---|
Physical Characteristics (Overall)
Conductor
AWG | Stranding | Material | Nominal Diameter | No. of Coax |
---|
22 | Solid | BCCS - Bare Copper Covered Steel | 0.025 in | 1 |
Insulation
Material | Nominal Diameter | Nominal Wall Thickness |
---|
PE - Polyethylene (Semi-Solid) | 0.146 in | 0.026 in |
Outer Shield
Type | Material | Coverage [%] |
---|
Braid | Bare Copper (BC) | 95% |
Outer Jacket
Material | Nominal Diameter | Nominal Wall Thickness |
---|
PVC - Polyvinyl Chloride (Non-Contaminating) | 0.242 in | 0.033 in |
Electrical Characteristics
Conductor DCR
Nominal Conductor DCR | Nominal Outer Shield DCR |
---|
40.5 Ohm/1000ft | 2.4 Ohm/1000ft |
Capacitance
Nom. Capacitance Conductor to Shield |
---|
13.0 pF/ft |
Inductance
Nominal Inductance |
---|
0.116 µH/ft |
Impedance
Nominal Characteristic Impedance |
---|
93 Ohm |
High Frequency (Nominal/Typical)
Frequency [MHz] | Nom. Insertion Loss |
---|
1 MHz | 0.3 dB/100ft |
10 MHz | 0.9 dB/100ft |
50 MHz | 1.9 dB/100ft |
100 MHz | 2.7 dB/100ft |
200 MHz | 3.8 dB/100ft |
400 MHz | 5.3 dB/100ft |
700 MHz | 7.3 dB/100ft |
900 MHz | 8.2 dB/100ft |
1000 MHz | 8.7 dB/100ft |
Delay
Nominal Velocity of Propagation (VP) [%] |
---|
85% |
Voltage
UL Voltage Rating | Voltage Rating [V] |
---|
300 V RMS | 750 V RMS |
Temperature Range
UL Temp Rating | 60°C |
---|
Operating Temperature Range | -40°C To +80°C |
---|
Mechanical Characteristics
Bulk Cable Weight | 34 lbs/1000ft |
---|
Max. Pull Tension | 66 lbs |
---|
Min. Bend Radius/Minor Axis | 2.5 in |
---|
Standards
NEC/(UL) Compliance | CMX |
---|
CEC/C(UL) Compliance | CMX |
---|
UL AWM Style Compliance | AWM 1354 (30 V 60°C) |
---|
RG Type | 62 |
---|
Military Compliance | MIL-DTL-17, M17/30-RG62, QPL |
---|
Qualified Products List (QPL) | Yes |
---|
Applicable Environmental and Other Programs
EU Directive 2000/53/EC (ELV) | Yes |
---|
EU Directive 2003/11/EC (BFR) | Yes |
---|
EU Directive 2011/65/EU (RoHS 2) | Yes |
---|
EU Directive 2012/19/EU (WEEE) | Yes |
---|
EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
---|
EU Directive Compliance | Yes |
---|
MII Order #39 (China RoHS) | Yes |
---|
Suitability
Suitability - Aerial | Yes - Black only, when supported by messenger wire |
---|
Suitability - Burial | No |
---|
Suitability - Hazardous Locations | No |
---|
Suitability - Indoor | Yes |
---|
Suitability - Outdoor | Yes - Black only |
---|
Flammability, LS0H, Toxicity Testing
UL Flammability | VW-1 |
---|
UL voltage rating | 300 V RMS |
---|
Plenum/Non-Plenum
History
Update and Revision | Revision Number: 0.335 Revision Date: 05-05-2023 |
---|
Documentation
Product Bulletins
Catalogs
Data Sheets