Low Temp Plastic Lead Wire, 20AWG (7x28) Tinned Copper, Conductive PO/PO Insulation, PVC Outer Jacket, AWM 3239 80C
Specifications
Specifications
Product Overview
Suitable Applications | internal wiring of electronic equipments, high voltage applications |
---|
Physical Characteristics (Overall)
Conductor
AWG | Stranding | Material | No. of Conductors |
---|
20 | 7x28 | TC - Tinned Copper | 1 |
Insulation
Material | Nominal Wall Thickness |
---|
PE - Polyethylene | 0.051 in |
Table Notes | .003 in. conductive polyethylene over stranding. |
---|
Outer Jacket
Material | Nominal Diameter | Nominal Wall Thickness |
---|
PVC - Polyvinyl Chloride | 0.201 in | 0.028 in |
Electrical Characteristics
High Frequency (Nominal/Typical)
Nom. Insertion Loss |
---|
6 dB/100m |
6 dB/100m |
6 dB/100m |
6 dB/100m |
Unbalanced Crosstalk
Typical Unbalanced NEXT % |
---|
6 MHz |
Voltage
Breakdown Voltage | Non-UL Description | Non-UL Voltage Rating | UL Voltage Rating |
---|
60,000 V (DC) | AC (60 Hertz) | 11,000 V RMS | 30,000 V DC |
Temperature Range
UL Temp Rating | 80°C |
---|
Operating Temperature Range | -30°C To +80°C |
---|
Mechanical Characteristics
Bulk Cable Weight | 19 lbs/1000ft |
---|
Max. Pull Tension | 15 lbs |
---|
Min. Bend Radius/Minor Axis | 3 in |
---|
Standards
UL AWM Style Compliance | AWM 3239 |
---|
Applicable Environmental and Other Programs
EU Directive 2000/53/EC (ELV) | Yes |
---|
EU Directive 2003/96/EC (BFR) | Yes |
---|
EU Directive 2011/65/EU (RoHS 2) | Yes |
---|
EU Directive 2012/19/EU (WEEE) | Yes |
---|
EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
---|
EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
---|
EU CE Mark | Yes |
---|
CA Prop 65 | Yes |
---|
MII Order #39 (China RoHS) | Yes |
---|
Flammability, LS0H, Toxicity Testing
UL Flammability | VW-1 |
---|
UL voltage rating | 30,000 V RMS |
---|
Plenum/Non-Plenum
History
Update and Revision | Revision Number: 0.400 Revision Date: 05-05-2023 |
---|
Documentation
Catalogs
Tools
Data Sheets