IEEE 802.3 Ethernet Transceiver 10BASE5, 20 and 22 AWG stranded tinned copper conductors, foam high-density polyethylene (22 AWG) and PVC (20 AWG) insulation, twisted pairs, Individually foil shielded pairs with overall tinned copper braid shield (95% coverage) drain wire, PVC jacket.
Specifications
Specifications
Product Overview
| Suitable Applications | IEEE 802.3 Transceiver Cable | 
|---|
Construction Details
Conductor
| Element | Number of Element | Size | Stranding | Material | 
|---|
| Data Pair(s) | 3 | 22 AWG | 7x30 | TC - Tinned Copper | 
| Pair(s) | 1 | 20 AWG | 7x28 | TC - Tinned Copper | 
Insulation
| Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code | Notes | 
|---|
| Data Pair(s) | PE - Polyethylene (Foam) | 0.017 in (0.43 mm) | 0.063 in (1.6 mm) | Yellow & Orange, Blue & Green, Black & White | HDPE | 
| Pair(s) | PVC - Polyvinyl Chloride | 0.012 in (0.30 mm) | 0.062 in (1.6 mm) | Gray & Purple |  | 
Inner Shield
| Element | Shield Type | Material | Coverage | Notes | 
|---|
| Data Pair(s) | Tape | Bi-Laminate (Alum+Poly) | 100% | Foil Out | 
| Pair(s) | Tape | Bi-Laminate (Alum+Poly) | 100% | Foil Out | 
Outer Shield
| Shield Type | Material | Coverage | 
|---|
| Braid | Tinned Copper (TC) | 95% | 
Outer Jacket
| Material | Nom. Thickness | Nom. Diameter | 
|---|
| PVC - Polyvinyl Chloride | 0.032 in (0.81 mm) | 0.316 in (8.03 mm) | 
| Overall Cable Diameter (Nominal) | 0.316 in (8.03 mm) | 
|---|
Electrical Characteristics
Electricals
| Element | Nom. Conductor DCR | Nom. Inner Shield DCR | Nom. Capacitance Cond-to-Cond | Nom. Capacitance Cond-to-Other (Conds + Shield) | Nom. Characteristic Impedence | Nom. Velocity of Prop. | Max. Current | 
|---|
| Pair(s) | 18.2 Ohm/1000ft | 12.4 Ohm/1000ft (40.7 Ohm/km) | 16.7 pF/ft (54.8 pF/m) | 29.5 pF/ft (96.8 pF/m) | 78 Ohm | 78% | 2 Amps per Conductor at 25ºC | 
| Pair(s) | 11.3 Ohm/1000ft (37.1 Ohm/km) | 12.4 Ohm/1000ft (40.7 Ohm/km) |  |  |  |  | 2.5 Amps per Conductor at 25ºC | 
Voltage
| UL Voltage Rating | 
|---|
| 300 V (CM), 30 V (AWM 2919) | 
Mechanical Characteristics
Temperature
| UL Temperature | Operating | 
|---|
| 80°C | -20°C to +80°C | 
Bend Radius
| Stationary Min. | Installation Min. | 
|---|
| 3.2 in (81 mm) | 3.2 in (81 mm) | 
| Max. Pull Tension | 160 lbs (73 kg) | 
|---|
| Bulk Cable Weight | 65 lbs/1000ft | 
|---|
Standards and Compliance
| Environmental Suitability | Indoor | 
|---|
| Flammability / Reaction to Fire | UL 1685 FT4 Loading, IEC 60332-1-2 | 
|---|
| CPR Compliance | CPR Euroclass: Eca | 
|---|
| NEC / UL Compliance | Article 800, CM | 
|---|
| AWM Compliance | AWM 2919 | 
|---|
| CEC / C(UL) Compliance | CM | 
|---|
| IEEE Compliance | IEEE 802.3 10Base5 | 
|---|
| European Directive Compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) | 
|---|
| UK Regulation Compliance | UKCA Mark | 
|---|
| APAC Compliance | China RoHS II (GB/T 26572-2011) | 
|---|
History
| Update and Revision | Revision Number: 0.572    Revision Date: 04-19-2023 | 
|---|
Documentation
Product Bulletins
Compliance Documentation
Data Sheets