IEEE 802.3 Ethernet Transceiver 10BASE5, 20 and 22 AWG stranded tinned copper conductors, foam high-density polyethylene (22 AWG) and PVC (20 AWG) insulation, twisted pairs, Individually foil shielded pairs with overall tinned copper braid shield (95% coverage) drain wire, PVC jacket.
Specifications
Specifications
Product Overview
Suitable Applications | IEEE 802.3 Transceiver Cable |
---|
Construction Details
Conductor
Element | Number of Element | Size | Stranding | Material |
---|
Data Pair(s) | 3 | 22 AWG | 7x30 | TC - Tinned Copper |
Pair(s) | 1 | 20 AWG | 7x28 | TC - Tinned Copper |
Insulation
Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code | Notes |
---|
Data Pair(s) | PE - Polyethylene (Foam) | 0.017 in (0.43 mm) | 0.063 in (1.6 mm) | Yellow & Orange, Blue & Green, Black & White | HDPE |
Pair(s) | PVC - Polyvinyl Chloride | 0.012 in (0.30 mm) | 0.062 in (1.6 mm) | Gray & Purple | |
Inner Shield
Element | Shield Type | Material | Coverage | Notes |
---|
Data Pair(s) | Tape | Bi-Laminate (Alum+Poly) | 100% | Foil Out |
Pair(s) | Tape | Bi-Laminate (Alum+Poly) | 100% | Foil Out |
Outer Shield
Shield Type | Material | Coverage |
---|
Braid | Tinned Copper (TC) | 95% |
Outer Jacket
Material | Nom. Thickness | Nom. Diameter |
---|
PVC - Polyvinyl Chloride | 0.032 in (0.81 mm) | 0.316 in (8.03 mm) |
Overall Cable Diameter (Nominal) | 0.316 in (8.03 mm) |
---|
Electrical Characteristics
Electricals
Element | Nom. Conductor DCR | Nom. Inner Shield DCR | Nom. Capacitance Cond-to-Cond | Nom. Capacitance Cond-to-Other (Conds + Shield) | Nom. Characteristic Impedence | Nom. Velocity of Prop. | Max. Current |
---|
Pair(s) | 18.2 Ohm/1000ft | 12.4 Ohm/1000ft (40.7 Ohm/km) | 16.7 pF/ft (54.8 pF/m) | 29.5 pF/ft (96.8 pF/m) | 78 Ohm | 78% | 2 Amps per Conductor at 25ºC |
Pair(s) | 11.3 Ohm/1000ft (37.1 Ohm/km) | 12.4 Ohm/1000ft (40.7 Ohm/km) | | | | | 2.5 Amps per Conductor at 25ºC |
Voltage
UL Voltage Rating |
---|
300 V (CM), 30 V (AWM 2919) |
Mechanical Characteristics
Temperature
UL Temperature | Operating |
---|
80°C | -20°C to +80°C |
Bend Radius
Stationary Min. | Installation Min. |
---|
3.2 in (81 mm) | 3.2 in (81 mm) |
Max. Pull Tension | 160 lbs (73 kg) |
---|
Bulk Cable Weight | 65 lbs/1000ft |
---|
Standards and Compliance
Environmental Suitability | Indoor |
---|
Flammability / Reaction to Fire | UL 1685 FT4 Loading, IEC 60332-1-2 |
---|
CPR Compliance | CPR Euroclass: Eca |
---|
NEC / UL Compliance | Article 800, CM |
---|
AWM Compliance | AWM 2919 |
---|
CEC / C(UL) Compliance | CM |
---|
IEEE Compliance | IEEE 802.3 10Base5 |
---|
European Directive Compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
---|
UK Regulation Compliance | UKCA Mark |
---|
APAC Compliance | China RoHS II (GB/T 26572-2011) |
---|
History
Update and Revision | Revision Number: 0.572 Revision Date: 04-19-2023 |
---|
Documentation
Product Bulletins
Compliance Documentation
Data Sheets