Computer EIA RS-232/423 Cable, 24 AWG stranded (7x32) tinned copper conductors, Datalene® insulation, overall Beldfoil® (100% coverage) + tinned copper braid shield (65% coverage), drain wire, PVC jacket.
Specifications
Specifications
Product Overview
| Suitable Applications | RS-232 Extended Distance & RS-423 Applications; Computer Communications; Low Voltage Analog Signals (4-20mA, 0-10V, ...); Low Voltage Digital Control (24V, …); Line Level Audio; Panel Wiring |
|---|
Construction Details
Conductor
| Element | Number of Element | Size | Stranding | Material |
|---|
| Conductor(s) | 6 | 24 AWG | 7x32 | TC - Tinned Copper |
Insulation
| Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code |
|---|
| Conductor(s) | PE - Polyethylene (Foam) | 0.013 in (0.33 mm) | 0.049 in (1.2 mm) | Black, White, Red, Green, Brown, Blue |
Outer Shield
| Shield Type | Material | Coverage | Drainwire Type |
|---|
| Tape | Bi-Laminate (Alum+Poly) | 100% | 24 AWG (7x32) TC |
| Braid | Tinned Copper (TC) | 65% | |
Outer Jacket
| Material | Nom. Thickness | Nom. Diameter |
|---|
| PVC - Polyvinyl Chloride | 0.035 in (0.89 mm) | 0.242 in (6.15 mm) |
| Overall Cable Diameter (Nominal) | 0.242 in (6.15 mm) |
|---|
Electrical Characteristics
Electricals
| Element | Nom. Conductor DCR | Nom. Capacitance Cond-to-Cond | Nom. Capacitance Cond-to-Other (Conds + Shield) | Nom. Velocity of Prop. | Max. Current |
|---|
| Conductor(s) | 24 Ohm/1000ft | 12 pF/ft (39 pF/m) | 22 pF/ft (72 pF/m) | 78% | 1.5 Amps per Conductor at 25ºC |
Voltage
| UL Voltage Rating |
|---|
| 300 V (CM), 30 V (UL AWM 2919) |
Mechanical Characteristics
Temperature
| UL Temperature | Operating |
|---|
| 60°C (UL CM);80°C (UL AWM 2464) | -30°C to +80°C |
Bend Radius
| Stationary Min. | Installation Min. |
|---|
| 2.9 in (74 mm) | 2.9 in (74 mm) |
| Max. Pull Tension | 68 lbs (31 kg) |
|---|
| Bulk Cable Weight | 34 lbs/1000ft |
|---|
Standards and Compliance
| Environmental Suitability | Indoor (Not Riser or Plenum), Indoor |
|---|
| Sustainability | CA Prop 65 |
|---|
| Flammability / Reaction to Fire | UL 1685 UL loading , IEC 60332-1-2 |
|---|
| CPR Compliance | CPR Euroclass: Eca |
|---|
| NEC / UL Compliance | Article 800, CM |
|---|
| AWM Compliance | AWM 2919 |
|---|
| CEC / C(UL) Compliance | CM |
|---|
| European Directive Compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
|---|
| UK Regulation Compliance | UKCA Mark |
|---|
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
|---|
Product Notes
| Notes | Datalene® insulation features include a low dielectric constant and a low dissipation factor for high-speed, low-distortion data handling. Physical properties include good crush resistance and light weight. |
|---|
History
| Update and Revision | Revision Number: 0.535 Revision Date: 01-20-2023 |
|---|
Documentation
Product Bulletins
Compliance Documentation
Data Sheets