Electronic, 3 Conductor 16AWG (19x29) Tinned Copper, PVC-NYL Insulation, Overall Tinned Copper Braid(90%) Shield, PVC Outer Jacket
Specifications
Specifications
Product Overview
Suitable Applications | MIL-W-16878 (Type B) Spec; up to 600V analog signals ; up to 600V voltage control |
---|
Construction Details
Conductor
Element | Number of Element | Size | Stranding | Material |
---|
Conductor(s) | 3 | 16 AWG | 19x29 | TC - Tinned Copper |
Insulation
Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code |
---|
Conductor(s) | PVC/Nylon - Polyvinyl Chloride + Nylon | 0.016 in (0.41 mm) | 0.088 in (2.2 mm) | White, Black, Red |
Outer Shield
Shield Type | Material | Coverage |
---|
Braid | Tinned Copper (TC) | 95% |
Outer Jacket
Material | Nom. Thickness | Nom. Diameter |
---|
PVC - Polyvinyl Chloride | 0.025 in (0.64 mm) | 0.264 in |
Overall Cable Diameter (Nominal) | 0.264 in. |
---|
Electrical Characteristics
Electricals
Nom. Conductor DCR | Nom. Capacitance Cond-to-Cond | Nom. Capacitance Cond-to-Other (Conds + Shield) | Max. Current |
---|
4.4 Ohm/1000ft | 58 pF/ft (190 pF/m) | 101 pF/ft (331 pF/m) | 6.5 Amps per Conductor at 25ºC |
Voltage
Mechanical Characteristics
Temperature
UL Temperature | Operating |
---|
105°C | -20°C To +105°C |
Bend Radius
Stationary Min. | Installation Min. |
---|
2.64 in (67.1 mm) | 2.64 in |
Max. Pull Tension | 120 lbs (54 kg) |
---|
Bulk Cable Weight | 52 lbs/1000ft |
---|
Standards and Compliance
Flammability / Reaction to Fire | IEC 60332-1-2 |
---|
CPR Compliance | CPR Euroclass: Eca |
---|
Military Compliance | MIL-W-16878E/17 (insulated conductor) |
---|
European Directive Compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
---|
UK Regulation Compliance | UKCA Mark |
---|
APAC Compliance | China RoHS II (GB/T 26572-2011) |
---|
History
Update and Revision | Revision Number: 0.390 Revision Date: 05-05-2023 |
---|
Documentation
Product Bulletins
Compliance Documentation
Data Sheets