Electronic, 1 Conductor 22AWG (19x34) Tinned Copper, PVC-NYL Insulation, Overall Tinned Copper Braid(90%) Shield, PVC Outer Jacket
Specifications
Specifications
Product Overview
Suitable Applications | MIL-W-16878 (Type B) Spec; up to 600V analog signals ; up to 600V voltage control |
---|
Construction Details
Conductor
Element | Number of Element | Size | Stranding | Material |
---|
Conductor(s) | 1 | 22 AWG | 19x34 | TC - Tinned Copper |
Insulation
Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code |
---|
Conductor(s) | PVC/Nylon - Polyvinyl Chloride + Nylon | 0.0125 in (0.318 mm) | 0.056 in (1.4 mm) | White |
Outer Shield
Shield Type | Material | Coverage |
---|
Braid | Tinned Copper (TC) | 92% |
Outer Jacket
Material | Nom. Thickness | Nom. Diameter |
---|
PVC - Polyvinyl Chloride | 0.01 in (0.25 mm) | 0.098 in |
Overall Cable Diameter (Nominal) | 0.098 in. |
---|
Electrical Characteristics
Electricals
Nom. Conductor DCR | Nom. Capacitance Cond-to-Shield | Max. Current |
---|
18.1 Ohm/1000ft | 100 pF/ft (330 pF/m) | 4.4 Amps per Conductor at 25ºC |
Voltage
Mechanical Characteristics
Temperature
UL Temperature | Operating |
---|
105°C | -20°C To +105°C |
Bend Radius
Stationary Min. | Installation Min. |
---|
0.98 in (25 mm) | 0.98 in |
Max. Pull Tension | 9.5 lbs (4.3 kg) |
---|
Bulk Cable Weight | 14 lbs/1000ft |
---|
Standards and Compliance
Flammability / Reaction to Fire | VW-1 |
---|
Military Compliance | MIL-W-16878E/17 (insulated conductor) |
---|
European Directive Compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
---|
APAC Compliance | China RoHS II (GB/T 26572-2011) |
---|
History
Update and Revision | Revision Number: 0.389 Revision Date: 05-05-2023 |
---|
Documentation
Product Bulletins
Compliance Documentation
Data Sheets