Flat Gray Ribbon Cable .050" Pitch, 9L280XX Series, 26 Conductor, 28 AWG (7x36) Tinned Copper, PVC Insulation
Specifications
Specifications
Product Overview
Suitable Applications | Internal interconnection, internal wiring of electronic equipment, reliable mass-termination to standard IDC connectors |
---|
Physical Characteristics (Overall)
Conductor
AWG | Stranding | Material |
---|
28 | 7x36 | TC - Tinned Copper |
Insulation
Material | Nominal Wall Thickness |
---|
PVC - Polyvinyl Chloride | 0.010 in |
Color Chart
Table Notes | First Conductor has Red Stripe |
---|
Construction and Dimensions
Conductor Spacing Center-Center | .050 +/- .002 in |
---|
Conductor Spacing Center-Center Outside | 1.250 +/- .008 in |
---|
OuterJacket1, Nominal Width | 1.300 +/- .008 in |
---|
OuterJacket1, Nom Thick Flat Section | 0.035 in |
---|
Electrical Characteristics
Conductor DCR
Nominal Conductor DCR |
---|
68.2 Ohm/1000ft |
Capacitance
Element | Nom. Capacitance Conductor to Conductor |
---|
@ 1 kHz (GSG) | 18 pF/ft |
@ 1 MHz (GS) | 10 pF/ft |
@ 1 MHz (GSG) | 15 pF/ft |
Min Insulation Resistance | 10,000 MOhm |
---|
Inductance
Element | Nominal Inductance |
---|
@ 1 MHz (GS) | 0.29 µH/ft |
@ 1 MHz (GSG) | 0.2 µH/ft |
Impedance
Nominal Characteristic Impedance | Nominal Characteristic Impedance Description |
---|
150 Ohm | (GS) |
105 Ohm | (GSG) |
High Frequency (Nominal/Typical)
Frequency [MHz] | Nom. Insertion Loss |
---|
10 MHz | 2.8 dB/100ft |
20 MHz | 4.8 dB/100ft |
30 MHz | 6.5 dB/100ft |
40 MHz | 8.3 dB/100ft |
50 MHz | 9.8 dB/100ft |
60 MHz | 12 dB/100ft |
70 MHz | 13 dB/100ft |
80 MHz | 14 dB/100ft |
90 MHz | 15.8 dB/100ft |
100 MHz | 17 dB/100ft |
Table Notes | GS=Ground-Signal Mode; GSG=Ground-Signal-Ground Mode |
---|
Delay
Nominal Delay | Nominal Velocity of Propagation (VP) [%] |
---|
1.4 ns/ft | 72% |
Unbalanced Crosstalk
Element | Typical Unbalanced NEXT % | Typical Unbalanced FEXT % | Typical Cross Talk Pulse Rise Time (ns) |
---|
10 ft. sample length | 4.8 | 7 | 3 ns |
10 ft. sample length | 3.5 | 4.7 | 5 ns |
10 ft. sample length | 3 | 3 | 7 ns |
Current
Max. Recommended Current [A] |
---|
1 Amp per Conductor at 20ºC |
Voltage
Dielectric Withstand Voltage | UL Voltage Rating |
---|
2000 V | 300 V |
Temperature Range
Operating Temperature Range | -40°C to +105°C |
---|
Mechanical Characteristics
Bulk Cable Weight | 30 lbs/1000ft |
---|
Standards
UL AWM Style Compliance | AWM 2651 |
---|
CSA AWM Compliance | I A |
---|
Applicable Environmental and Other Programs
EU Directive 2000/53/EC (ELV) | Yes |
---|
EU Directive 2003/96/EC (BFR) | Yes |
---|
EU Directive 2011/65/EU (RoHS 2) | Yes |
---|
EU Directive 2012/19/EU (WEEE) | Yes |
---|
EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
---|
EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
---|
EU CE Mark | Yes |
---|
CA Prop 65 (CJ for Wire and Cable) | Yes |
---|
MII Order #39 (China RoHS) | Yes |
---|
Suitability
Flammability, LS0H, Toxicity Testing
UL Flammability | VW-1 |
---|
UL voltage rating | 300 V |
---|
Plenum/Non-Plenum
History
Update and Revision | Revision Number: 0.388 Revision Date: 05-05-2023 |
---|
Documentation
Related Webpages
Data Sheets