Flat Gray Ribbon Cable .050" Pitch, 9L280XX Series, 50 Conductor, 28 AWG (7x36) Tinned Copper, PVC Insulation
Specifications
Specifications
Product Overview
Suitable Applications | Internal interconnection, internal wiring of electronic equipment, reliable mass-termination to standard IDC connectors |
---|
Construction Details
Conductor
Element | Number of Element | Size | Stranding | Material |
---|
Conductor(s) | 50 | 28 AWG | 7x36 | TC - Tinned Copper |
Insulation
Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code | Notes |
---|
Conductor(s) | PVC - Polyvinyl Chloride | 0.010 in (0.25 mm) | 0.035 in (0.89 mm) | Gray | A Red Stripe over the first conductor |
Conductor Spacing Center-Center | .050 +/- .002 in |
---|
Conductor Spacing Center-Center Outside | 2.450 +/- .011 in |
---|
Electrical Characteristics
Electricals
Nom. Conductor DCR | Nom. Capacitance Cond-to-Cond | Nom. Characteristic Impedence | Nom. Delay | Nom. Inductance | Nom. Velocity of Prop. | Max. Current |
---|
68.2 Ohm/1000ft | 18 pF/ft (59 pF/m) | 150 Ohm | 1.4 ns/ft (4.6 ns/m) | 0.29 µH/ft (0.95 µH/m) | 72% | 1 Amp per Conductor at 20ºC |
| 10 pF/ft (33 pF/m) | 105 Ohm | | 0.2 µH/ft (0.66 µH/m) | | |
| 15 pF/ft (49 pF/m) | | | | | |
Unbalanced Crosstalk
Element | Typical Unbalanced NEXT % | Typical Unbalanced FEXT % | Typical Cross Talk Pulse Rise Time |
---|
10 ft. sample length | 4.8 | 7 | 3 ns |
10 ft. sample length | 3.5 | 4.7 | 5 ns |
10 ft. sample length | 3 | 3 | 7 ns |
High Frequency (Nominal/Typical)
Frequency [MHz] | Nom. Insertion Loss (Attenuation) |
---|
10 | 2.8 dB/100ft |
20 | 4.8 dB/100ft |
30 | 6.5 dB/100ft |
40 | 8.3 dB/100ft |
50 | 9.8 dB/100ft |
60 | 12 dB/100ft |
70 | 13 dB/100ft |
80 | 14 dB/100ft |
90 | 15.8 dB/100ft |
100 | 17 dB/100ft |
Table Notes | GS=Ground-Signal Mode; GSG=Ground-Signal-Ground Mode |
---|
Voltage
Mechanical Characteristics
Temperature
UL Temperature | Operating |
---|
105°C | -40°C to +105°C |
Bend Radius
Installation Min. |
---|
0.5 in (13 mm) |
Bulk Cable Weight | 65 lbs/1000ft |
---|
Standards and Compliance
Environmental Suitability | Indoor |
---|
Flammability / Reaction to Fire | VW-1 |
---|
AWM Compliance | AWM 2651, AWM 1/11, A |
---|
European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
---|
APAC Compliance | China RoHS II (GB/T 26572-2011) |
---|
History
Update and Revision | Revision Number: 0.499 Revision Date: 01-20-2023 |
---|
Documentation
Related Webpages
Data Sheets