UL Type TC-ER (1277) PVC-Nylon/PVC, 2+G Conductor 14AWG (7x22) Bare Copper, PVC-NYL Insulation E2 Color Code, 1 Conductor 14 (7x22) Bare Copper Insulated Ground, Overall Beldfoil® Shield, Black PVC Outer Jacket, 600V TC-ER 150V NPLF 90C Dry 75C Wet SUN RES DIR BUR
Specifications
Specifications
Physical Characteristics (Overall)
Conductor
| Element | AWG | Stranding | Material | No. of Conductors |
|---|
| Conductor(s) | 14 | 7x22 | BC - Bare Copper | 2 |
| Ground | 14 | 7x22 | BC - Bare Copper | 1 |
Insulation
| Material | Nominal Diameter | Nominal Wall Thickness |
|---|
| PVC/Nylon - Polyvinyl Chloride + Nylon | 0.116 in | 0.024 in |
| PVC/Nylon - Polyvinyl Chloride + Nylon | 0.0116 in | 0.024 in |
Color Chart
| Number | Color |
|---|
| 1 | Black |
| 2 | Red |
| Ground | Green |
Outer Shield
| Type | Material | Material Trade Name | Coverage [%] | Drainwire Material | Drainwire AWG |
|---|
| Tape | Bi-Laminate (Alum+Poly) | Beldfoil® | 100% | TC - Tinned Copper | 14 |
Outer Jacket
| Material | Nominal Diameter | Nominal Wall Thickness |
|---|
| PVC - Polyvinyl Chloride | 0.348 in | 0.047 in |
Electrical Characteristics
Conductor DCR
| Nominal Conductor DCR |
|---|
| 2.52 Ohm/1000ft |
Current
| Max. Recommended Current [A] |
|---|
| 25 Amps per Conductor at 30ºC |
Voltage
| Description | UL Description | UL Voltage Rating | Voltage Rating [V] |
|---|
| Type TC | TC | 600 V RMS | 600 V RMS |
| NPLF | 150 V RMS | |
Temperature Range
| UL Temp Rating | 90°C Wet/Dry |
|---|
| Operating Temperature Range | '-30°C To +90°C |
|---|
Mechanical Characteristics
| UV Resistance | Yes |
|---|
| Bulk Cable Weight | 89 lbs/1000ft |
|---|
| Max. Pull Tension | 64 lbs |
|---|
| Min. Bend Radius/Minor Axis | 3.48 in |
|---|
Standards
| NEC Articles | Article 336 |
|---|
| NEC/(UL) Compliance | NPLF, TC-ER, THHN/THWN Singles |
|---|
Applicable Environmental and Other Programs
| EU Directive 2000/53/EC (ELV) | Yes |
|---|
| EU Directive 2003/11/EC (BFR) | Yes |
|---|
| EU Directive 2011/65/EU (RoHS 2) | Yes |
|---|
| EU Directive 2012/19/EU (WEEE) | Yes |
|---|
| EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
|---|
| EU Directive Compliance | Yes |
|---|
| EU CE Mark | Yes |
|---|
Suitability
| Suitability - Burial | Yes |
|---|
| Suitability - Indoor | Yes |
|---|
| Suitability - Outdoor | Yes |
|---|
| Suitability - Sunlight Resistance | Yes |
|---|
Flammability, LS0H, Toxicity Testing
| UL Flammability | UL 1685 UL Loading |
|---|
| IEEE Flammability | 1202 |
|---|
| UL voltage rating | 600 V RMS (Type TC) |
|---|
Plenum/Non-Plenum
History
| Update and Revision | Revision Number: 0.49 Revision Date: 04-14-2023 |
|---|
Documentation
Catalogs
Tools
Data Sheets