UL Type TC (1277) PVC-Nylon/PVC, 3 Conductor 10AWG (7x18) Bare Copper, PVC-NYL Insulation E2 Color Code, Black PVC Outer Jacket, 600V TC-ER 90C Dry/Wet SUN RES DIR BUR
Specifications
Specifications
Physical Characteristics (Overall)
Conductor
Element | AWG | Stranding | Material | Nominal Diameter | No. of Conductors |
---|
Conductor(s) | 10 | 7x18 | BC - Bare Copper | 0.110 in | 3 |
Insulation
Material | Nominal Diameter |
---|
PVC/Nylon - Polyvinyl Chloride + Nylon | 0.164 in |
Color Chart
Number | Color |
---|
1 | Black |
2 | Red |
3 | Blue |
Outer Jacket
Material | Nominal Diameter | Nominal Wall Thickness |
---|
PVC - Polyvinyl Chloride | 0.450 in | 0.047 in |
Electrical Characteristics
Conductor DCR
Nominal Conductor DCR |
---|
1.04 Ohm/1000ft |
Current
Max. Recommended Current [A] |
---|
40 Amps per Conductor at 30ºC |
Voltage
UL Description | UL Voltage Rating | Voltage Rating [V] |
---|
TC | 600 V RMS (Type TC) | 600 V RMS (Type TC) |
Temperature Range
UL Temp Rating | 90°C Dry, 75°C Wet |
---|
Operating Temperature Range | -25°C To +90°C |
---|
Mechanical Characteristics
UV Resistance | Yes |
---|
Min Bend Radius (Overall) | 4.5 in |
---|
Min. Bend Radius/Minor Axis | 1.80 in |
---|
Standards
Applicable Environmental and Other Programs
EU Directive 2000/53/EC (ELV) | Yes |
---|
EU Directive 2011/65/EU (RoHS 2) | Yes |
---|
EU Directive 2012/19/EU (WEEE) | Yes |
---|
EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
---|
EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
---|
EU CE Mark | Yes |
---|
Suitability
Suitability - Burial | Yes |
---|
Suitability - Indoor | Yes |
---|
Suitability - Outdoor | Yes |
---|
Suitability - Sunlight Resistance | Yes |
---|
Flammability, LS0H, Toxicity Testing
UL Flammability | UL1685 Vertical Tray Flame Test |
---|
UL voltage rating | 600 V RMS (Type TC) |
---|
History
Update and Revision | Revision Number: 0.48 Revision Date: 04-08-2022 |
---|
Documentation
Catalogs
Tools
Data Sheets