UL Type TC (1277) PVC-Nylon/PVC, 15 Conductor 10AWG (7x18) Bare Copper, PVC-NYL Insulation E2 Color Code, Overall Beldfoil® Shield, Black PVC Outer Jacket, 600V TC-ER 90C Dry/Wet SUN RES DIR BUR
Specifications
Specifications
Physical Characteristics (Overall)
Conductor
Element | AWG | Stranding | Material | No. of Conductors |
---|
Conductor(s) | 10 | 7x18 | BC - Bare Copper | 15 |
Insulation
Material | Nominal Diameter | Nominal Wall Thickness |
---|
PVC/Nylon - Polyvinyl Chloride + Nylon | 0.164 in | 0.026 in |
Color Chart
Number | Color |
---|
1 | Black and Numbered 1 |
2 | Red and Numbered 2 |
3 | Blue and Numbered 3 |
4 | Orange and Numbered 4 |
5 | Yellow and Numbered 5 |
6 | Brown and Numbered 6 |
7 | Red/Black and Numbered 7 |
8 | Blue/Black and Numbered 8 |
9 | Orange/Black and Numbered 9 |
10 | Yellow/Black and Numbered 10 |
11 | Brown/Black and Numbered 11 |
12 | Black/Red and Numbered 12 |
13 | Blue/Red and Numbered 13 |
14 | Orange/Yellow and Numbered 14 |
15 | Yellow/Red and Numbered 15 |
Outer Shield
Type | Material | Material Trade Name | Coverage [%] | Drainwire Material | Drainwire AWG |
---|
Tape | Bi-Laminate (Alum+Poly) | Beldfoil® | 100% | TC - Tinned Copper | 10 |
Outer Jacket
Material | Nominal Diameter | Nominal Wall Thickness |
---|
PVC - Polyvinyl Chloride | 0.941 in | 0.083 in |
Electrical Characteristics
Conductor DCR
Nominal Conductor DCR |
---|
1.04 Ohm/1000ft |
Current
Max. Recommended Current [A] |
---|
20 Amps per Conductor at 30ºC |
Voltage
Description | UL Description | UL Voltage Rating | Voltage Rating [V] |
---|
Type TC | TC | 600 V RMS (Type TC) | 600 V RMS (Type TC) |
Temperature Range
UL Temp Rating | 90°C Dry, 90°C Wet |
---|
Operating Temperature Range | -30°C To +90°C |
---|
Wet Temp Range | -30°C To +90 °C |
---|
Dry Temp Range | -30°C To +90 °C |
---|
Mechanical Characteristics
UV Resistance | Yes |
---|
Bulk Cable Weight | 768 lbs/1000ft |
---|
Max. Pull Tension | 1245 lbs |
---|
Min Bend Radius (Overall) | 9.4 in |
---|
Min. Bend Radius/Minor Axis | 9.41 in |
---|
Standards
NEC/(UL) Compliance | TC-ER, THWN-2 |
---|
Applicable Environmental and Other Programs
EU Directive 2000/53/EC (ELV) | Yes |
---|
EU Directive 2011/65/EU (RoHS 2) | Yes |
---|
EU Directive 2012/19/EU (WEEE) | Yes |
---|
EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
---|
EU Directive Compliance | Yes |
---|
EU CE Mark | Yes |
---|
Suitability
Suitability - Burial | Yes |
---|
Suitability - Indoor | Yes |
---|
Suitability - Outdoor | Yes |
---|
Suitability - Sunlight Resistance | Yes |
---|
Flammability, LS0H, Toxicity Testing
UL Flammability | UL 1685 UL Loading |
---|
IEEE Flammability | 1202 |
---|
UL voltage rating | 600 V RMS (Type TC) |
---|
Plenum/Non-Plenum
History
Update and Revision | Revision Number: 0.50 Revision Date: 04-14-2023 |
---|
Documentation
Catalogs
Tools
Data Sheets