FiberExpress Tactical Cable, 12-Fiber, OS2, with Black Jacket, Small & Lightweight, Ideal for repeated deployment and retrieval cycles, superior crush resistance.
Specifications
Specifications
Product Overview
| Suitable Applications | Outdoor |
|---|
Construction
Fiber Cable Construction
| Fiber Type | Fiber Count |
|---|
| OS2 | 12 |
| Fiber Color Coding | TIA-598-D |
|---|
Buffer Specification
| Buffer Material | Buffer Diameter |
|---|
| Thermoplastic | 900 +35um/-50um |
| Bulk Cable Weight | 39 lbs/1000ft |
|---|
Jacket Specifications
| Number of Jackets | Single Jacket |
|---|
Outer Jacket Specifications
Outer Jacket
| Material | Nominal Diameter |
|---|
| PUR - Polyurethane | 0.24 |
| Color | Black |
|---|
| Number of Ripcords | 1 |
|---|
Optical Characteristics
| Mode Field Diameter | 9.2um |
|---|
| Max. Attenuation at 1310 nm | 0.50 dB/km |
|---|
| Max. Attenuation at 1550 nm | 0.50 dB/km |
|---|
| Wavelength | 1310/1550 |
|---|
| 10 Gigabit Ethernet Performance | 10,000/40,000 |
|---|
| 1 Gigabit Ethernet Performance | 5000/- |
|---|
Mechanical Characteristics
Mechanical Tests
| Description | Requirement/Value |
|---|
| Cable Min. Bend Radius Installation (Short Term) | 20x |
| Cable Min. Bend Radius Operation (Long Term) | 10x |
| Cable Max. Tensile Strength Installation (Short Term) | 330 N (74 lbf) |
| Cable Max. Tensile Strength Operation (Long Term) | 150 N (34 lbf) |
Temperature Range
| Operating Temperature Range | -46C to +85C |
|---|
| Installation Temperature Range | -55°C To +85°C |
|---|
| Storage Temperature Range | -70°C To +85°C |
|---|
Standards
History
| Update and Revision | Revision Number: 0.37 Revision Date: 11-09-2022 |
|---|
Documentation
Product Bulletins
Catalogs
Warranties
Data Sheets