RailTuff Railway Approved Cat 5e, PROFINET, AWG 22(19), HiFlex, Premium Cross-linked LSNH Insulation and Jacket, Heavy Shielded, DIN 5510-2 level 1 to 4, EN 50155 Flame Resistance acc EN 45545-2, IEC 60332-1-2, EN 50305 & IEC 60332-3-25 cat D, EN 45545-2 (Class R15 and R16 HL3), Oil Resistance,, ECE R118.03
Specifications
Specifications
Product Overview
| Suitable Applications | PROFINET, For use in railway applications such as rolling stock, buses or other vehicles, cable meets the requirements of the relevant parts of international railway standards like DIN 5510-2, EN 50153, EN 50155, EN 50305 and EN 45545-2, ECE R118.03 |
|---|
Construction Details
Conductor
| Size | Stranding | Material | Number of Pairs | Number of Element |
|---|
| 22 AWG | 19x0.15 mm | TC - Tinned Copper | 2 | 4 |
| Table Notes | IEC 60228 class 5 |
|---|
Insulation
| Material | Nom. Insulation Diameter | Color Code |
|---|
| PO - Polyolefin | 1.57 mm (0.0618 in) | White & Blue & Yellow & Orange |
| | 1 Quad |
Cable Core
| Description |
|---|
| 1 quad with center filler |
Inner Jacket
| Material | Nom. Diameter |
|---|
| LSZH - Low Smoke Zero Halogen (Flame Retardant) | 4.3 mm (0.17 in) |
Outer Shield
| Shield Type | Material | Coverage |
|---|
| Tape | Bi-Laminate (Alum+Poly) | |
| Braid | Tinned Copper (TC) | 80% |
Outer Jacket
| Material | Nom. Diameter |
|---|
| LSZH - Low Smoke Zero Halogen (Flame Retardant) | 6.7 mm (0.26 in) |
| Table Notes | e-Beamed to Cross-link |
|---|
| Overall Cable Diameter (Nominal) | 6.7 mm (0.26 in) |
|---|
Electrical Characteristics
Electricals
| Max. Conductor DCR | Nom. Characteristic Impedance |
|---|
| 57.1 Ohm/km | 100 Ohm |
Delay
| Max. Delay | Nom. Velocity of Prop. |
|---|
| 530 ns/100m | 66% |
High Frequency
| Frequency [MHz] | Max. Insertion Loss (Attenuation) | Min. NEXT [dB] | Min. FEXT [dB] |
|---|
| 1 | 2.1 dB/100m | 65.3 | 64 |
| 4 | 4.1 dB/100m | 56.3 | 52 |
| 10 | 6.5 dB/100m | 50 | 43.8 |
| 16 | 8.3 dB/100m | 47 | 40 |
| 31.25 | 11.7 dB/100m | 42.9 | 33.9 |
| 62.5 | 17 dB/100m | 38.4 | 28 |
| 100 | 22 dB/100m | 35.3 | 24 |
| Table Notes | IEC 60288-2-2 and ISO/IEC 11801 ed. 2.0, Cat. 5e |
|---|
Transfer Impedance
| Frequency | Max. Transfer Impedance |
|---|
| 10 Mhz | Max. 10 mOhm/m |
Voltage
Mechanical Characteristics
Temperature
| Operating | Installation | Storage |
|---|
| -40°C to +90°C | -5°C To +50°C | -40°C to +90°C |
Bend Radius
| Stationary Min. | Installation Min. |
|---|
| 33.5 mm (1.32 in) | 67 mm |
| Bulk Cable Weight | 68 kg/km |
|---|
Standards and Compliance
| Environmental Suitability | Indoor |
|---|
| Flammability / Reaction to Fire | IEC 60332-1-2, IEC 60332-2-25, UN ECE R118.03 |
|---|
| Data Category | Category 5e |
|---|
| ISO/IEC Compliance | IEC 61034-2 - Smoke Density Min Transmittance = 70% |
|---|
| CENELEC Compliance | EN 45545-2 |
|---|
| European Halogen Free Standards | IEC 62821-1 Halogen Free Compliance = Yes, IEC 60754-1 - Halogen Amount = Zero, IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity = 10 µS/mm, IEC 60754-2 - Halogen Acid Gas Amount - Min. pH = 4.3 |
|---|
| European Directive Compliance | EU CE Mark |
|---|
History
| Update and Revision | Revision Number: 0.263 Revision Date: 04-04-2023 |
|---|