12 PAIR AES/EBU, 26AWG/0.14mm², ISTP, FLEX, LSZH, STAGE
Specifications
Specifications
Product Overview
| Suitable Applications | Digital multi-modulation cable used in professional studios; For the transmission of analogue and digital audio signals; Designed to meet the requirements of the AES/EBU specification; The cable is very flexible and has a small outer diameter for use in applications where space is limited | 
|---|
Physical Characteristics (Overall)
Conductor
| AWG | Stranding | Material | Cross Section | Construction n x D | 
|---|
| 26 | 7x34 | TC - Tinned Copper | 0.14 mm² | 7x0.16 mm | 
| Conductor Count | 24 | 
|---|
| Total Number of Pairs | 12 | 
|---|
Insulation
| Type | Material | Nominal Diameter | Diameter +/- Tolerance | 
|---|
| Insulation | PE - Polyethylene (Foam) | 1.1 mm | 0.03 mm | 
Color Chart
| Number | Color | 
|---|
| Pair 1 t/m 12 | White & Blue | 
Inner Shield
| Type | Material | Nominal Diameter | Min. Coverage [%] | 
|---|
| Spiral Serve / Screen | Tinned Copper (TC) | 2.40 mm | 90% | 
Inner Jacket
| Material | Nominal Diameter | Diameter +/- Tolerance | 
|---|
| Nylon | 2.8 mm | 0.1 mm | 
Outer Shield
| Type | Material | Nominal Diameter | Min. Coverage [%] | 
|---|
| Braid | Tinned Copper (TC) | 10.8 mm | 90% | 
Outer Jacket
| Material | Nominal Diameter | Diameter +/- Tolerance | 
|---|
| LSZH - Low Smoke Zero Halogen (Flame Retardant) | 12.8 mm | 0.5 mm | 
Construction and Dimensions
Cabling
| Description | 
|---|
| 12 pairs covered with 2 non-woven separating foils | 
Electrical Characteristics
Conductor DCR
| Max. Conductor DCR | 
|---|
| 130 Ohm/km | 
Capacitance
| Nom. Capacitance Conductor to Conductor | 
|---|
| 50 pF/m | 
Impedance
| Frequency [MHz] | Nominal Characteristic Impedance | Nominal Characteristic Tolerance | 
|---|
| 0.1 - 6 | 110 Ohm | +/- 15 Ohm | 
High Frequency (Nominal/Typical)
| Frequency [MHz] | Nom. Insertion Loss | 
|---|
| 1 MHz | 2.3 dB/100m | 
| 6 MHz | 9.5 dB/100m | 
| 10 MHz | 16 dB/100m | 
Delay
| Nominal Velocity of Propagation (VP) [%] | 
|---|
| 60% | 
Temperature Range
| Other Temp Range | -25 to +70 °C | 
|---|
Mechanical Characteristics
| Min. Bend Radius During Installation | 128 mm | 
|---|
| Min. Bend Radius During Operation | 192 mm | 
|---|
Applicable Environmental and Other Programs
| Environmental Space | Indoor | 
|---|
History
| Update and Revision | Revision Number: 0.158    Revision Date: 11-09-2022 | 
|---|
Documentation
Product Bulletins
Catalogs
Technical Resources
Data Sheets