Belden

BPB52L1F - CAT5 100Ω 4x22AWG Profinet Type B fire resistant cable

(No reviews yet) Write a Review
SKU:
BPB52L1F
Shipping:
Calculated at Checkout
$0.00

Description

CAT5 100Ω 4x22AWG Profinet Type B fire resistant cable, IEC 60332-23, EN 50200, EN50289-4-16, 80C, 300V, ROHS

Specifications

Specifications

Product Overview

Suitable ApplicationsFor railway Ethernet Networking, Fire resistance, ProfiNet Application

Construction Details

Conductor

SizeMaterial
22 AWGTC - Tinned Copper

Insulation

MaterialNom. Insulation DiameterColor Code
PO - Polyolefin1.4 mm (0.055 in)White, Yellow, Blue, Orange
Table NotesFire resistance tape wrapped over insulated cores

Outer Shield

Shield TypeMaterialCoverageNotes
TapePolyester + Bi-Laminate (Alum+Poly)
BraidTinned Copper (TC)80%Fire resistance tape wrapped over braid

Outer Jacket

Material
LSZH - Low Smoke Zero Halogen (Flame Retardant)
Table NotesE-beam cross-linked LSZH
Overall Cable Diameter (Nominal)7.3 mm (0.29 in)

Electrical Characteristics

Electricals

Max. Conductor DCR
59.4 Ω/km
Table NotesNom. fitted Impedance (Ω) 100 & Nom. Mutual Capacitance 56 pF/m

High Frequency

Frequency [MHz]Max. Insertion Loss (Attenuation)Min. NEXT [dB]Min. RL (Return Loss) [dB]Min. Coupling Attenuation [dB]
44.9 dB/100 m5323
86.9 dB/100 m48.524.5
107.8 dB/100 m4725
169.9 dB/100 m43.925
2011.1 dB/100 m42.525
2512.5 dB/100 m4124.2
31.314.1 dB/100 m39.623.380
4016.1 dB/1003822.480
62.520.4 dB/100 m35.120.780
10026.4 dB/100 m321980

Voltage

Voltage RatingBreakdown Voltage
300 V2 kVac/min

Mechanical Characteristics

Temperature

Operating
-40 ℃ to + 80℃
Table NotesNom. Bulk Weight of cable 70 kg/km

Standards and Compliance

Flammability / Reaction to FireIEC 60332-1-2, IEC 60332-3-25, IEC 60331-23, BS EN 50200 PH120
ISO/IEC ComplianceIEC 61156-2, IEC 61034-2 - Smoke Density Min Transmittance = 70%
CENELEC ComplianceEN 50289
European Halogen Free StandardsIEC 60754-1 - Halogen Amount = 0.5%, IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity = 10 , IEC 60754-2 - Halogen Acid Gas Amount - Min. pH = 4.3
European Directive ComplianceEU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2)
APAC ComplianceChina RoHS II (GB/T 26572-2011)
Other Standard Compliance(s)TJ/CL 313

Product Notes

NotesToxicity of insulation (EN 45545-2 Table 5-R15 and R16-HL3) ≦ 6 ; Toxicity of jacket (EN 45545-2 Table 5-R15 and R16-HL3) ≦ 6 ; Hazard level (EN 45545-2) HL3 ; IEC 61156-6, UL 758

History

Update and RevisionRevision Number: 0.13 Revision Date: 12-05-2022
View AllClose