Belden
C5582 - Teck90 1000V, 4+G C #8+10 Str BC, XLPE Ins M4, PVC Jkt, AIA Armor, Blk PVC Jkt, CSA HL SUN RES -40C
- SKU:
- C5582
- Shipping:
- Calculated at Checkout
Description
Teck90 1000V, 4+G Conductor 8+10AWG (7x16H) Bare Copper, XLPE Insulation M4 Color Code, PVC Inner Jacket, Aluminum Interlock Armor, Black PVC Outer Jacket, CSA HL SUN RES -40C
Specifications
Specifications
Put-Up Type | Reel |
---|
Product Overview
Suitable Applications | CEC Power and Control Applications up to 600V |
---|
Construction Details
Conductor
Element | Number of Element | Size | Stranding | Material |
---|---|---|---|---|
Conductor(s) | 4 | 8 AWG | 7x17 | BC - Bare Copper |
Ground Wire | 1 | 10 AWG | 7x18 | BC - Bare Copper |
Insulation
Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code |
---|---|---|---|---|
Conductor(s) | XLP, XLPO, XLPE (Thermoset) | 0.045 in (1.1 mm) | 0.234 in mm | Black, Red, Blue, White |
Ground Wire | No Insulation |
Outer Shield
Material |
---|
No Shield |
Inner Jacket
Material | Nom. Thickness | Nom. Diameter |
---|---|---|
PVC - Polyvinyl Chloride | 0.063 in (1.6 mm) | 0.707 in (18.0 mm) |
Armor
Armor Type & Material | Diameter Over Armor |
---|---|
AIA - Aluminum Interlock Armor | 0.932 in (23.7 mm) |
Outer Jacket
Material | Nom. Thickness | Nom. Diameter | Ripcord |
---|---|---|---|
PVC - Polyvinyl Chloride | 0.048 in (1.2 mm) | 1.028 in (26.11 mm) | Yes |
Overall Cable Diameter (Nominal) | 1.028 in (26.11 mm) |
---|
Electrical Characteristics
Electricals
Element | Nom. Conductor DCR | Max. Current |
---|---|---|
Conductor(s) | 0.667 Ohm/1000ft | 44 Amps per Conductor at 30ºC |
Ground Wire | 1.06 Ohm/1000ft (3.48 Ohm/km) |
Voltage
Voltage Rating |
---|
1000 V (TECK 90) |
Mechanical Characteristics
Temperature
Operating | Installation |
---|---|
-40°C To +90°C | -25°C To +90°C |
Bend Radius
Stationary Min. | Installation Min. |
---|---|
8.22 in (209 mm) | 8.22 in (209 mm) |
Max. Pull Tension | 1190.4 lbs (539.96 kg) |
---|---|
Bulk Cable Weight | 548 lbs/1000ft |
Standards and Compliance
Environmental Suitability | Indoor, Outdoor, Sunlight Resistance, UV Resistance, Burial |
---|---|
CEC / C(UL) Compliance | TECK 90, HL |
European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
APAC Compliance | China RoHS II (GB/T 26572-2011) |
History
Update and Revision | Revision Number: 0.176 Revision Date: 01-23-2023 |
---|
Documentation
Catalogs
Technical Resources
Videos
Compliance Documentation
Data Sheets
Additional Information
Variant_Options: |
Item #|Putup Type|UPC |
Variant_Options C5582 0101000: |
C5582 0101000|Reel|612825283492 |
Variant_Options C5582 0101640: |
C5582 0101640|Reel|612825283508 |
Variant_Options C5582 0102000: |
C5582 0102000|Reel| |
Variant_Options C5582 0103280: |
C5582 0103280|Reel|612825283522 |
Variant_Options C5582 0104000: |
C5582 0104000|Reel|612825283539 |
Variant_Options C5582 0107500: |
C5582 0107500|Reel|612825283553 |
Variant_Options C5582 0109840: |
C5582 0109840|Reel| |