Indoor/Outdoor Digital Electricity™ Copper Cable, 8 Twisted Pair 16 AWG (7x24) Stranded Tinned Copper, PVC insulation, Unshielded, PVC Jacket, CL4, CMG
Specifications
Specifications
Product Overview
Suitable Applications | Digital Electricity™, Fault Managed Power Systems (FMPS), remote powering, wet locations, in-conduit |
---|
Physical Characteristics (Overall)
Conductor
AWG | Stranding | Material | No. of Pairs |
---|
16 | 7x24 | TC - Tinned Copper | 8 |
Conductor Count | 16 |
---|
Total Number of Pairs | 8 |
---|
Insulation
Material | Nominal Wall Thickness |
---|
PVC - Polyvinyl Chloride | 0.017 in |
Color Chart
Number | Color |
---|
1 | Black & Red |
2 | Black & White |
3 | Black & Green |
4 | Black & Blue |
5 | Black & Yellow |
6 | Black & Brown |
7 | Black & Orange |
8 | Red & White |
Outer Jacket
Material | Nominal Diameter | Nominal Wall Thickness |
---|
PVC - Polyvinyl Chloride | 0.589 in | 0.043 in |
Electrical Characteristics
Conductor DCR
Nominal Conductor DCR |
---|
4.55 Ohm/1000ft |
Capacitance
Nom. Capacitance Conductor to Conductor |
---|
24.5 pF/ft |
Current
Max. Recommended Current [A] |
---|
5.5 Amps per Conductor at 25ºC (35°C Temperature Rise) |
Voltage
UL Voltage Rating |
---|
450 V RMS |
Temperature Range
UL Temp Rating | 105°C |
---|
Operating Temperature Range | -30°C To +105°C |
---|
Mechanical Characteristics
Bulk Cable Weight | 229 lbs/1000ft |
---|
Max. Pull Tension | 570 lbs |
---|
Min. Bend Radius/Minor Axis | 5.81 in |
---|
Standards
NEC Articles | Article 725, Article 800 |
---|
NEC/(UL) Compliance | CL4, CL3, CMG |
---|
CEC/C(UL) Compliance | CMG |
---|
UL AWM Style Compliance | AWM 2464 |
---|
Applicable Environmental and Other Programs
EU Directive 2000/53/EC (ELV) | Yes |
---|
EU Directive 2003/11/EC (BFR) | Yes |
---|
EU Directive 2011/65/EU (RoHS 2) | Yes |
---|
EU Directive 2012/19/EU (WEEE) | Yes |
---|
EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
---|
EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
---|
EU CE Mark | Yes |
---|
EU REACH SVHC Compliance (yyyy-mm-dd) | 2019-05-13 |
---|
Suitability
Suitability - Indoor | Yes |
---|
Suitability - Outdoor | Yes |
---|
Suitability - Sunlight Resistance | Yes |
---|
Flammability, LS0H, Toxicity Testing
CSA/C(UL) Flammability | FT4 |
---|
UL Flammability | UL 1685 FT4 Loading |
---|
IEEE Flammability | 1202 |
---|
History
Update and Revision | Revision Number: 0.128 Revision Date: 04-24-2023 |
---|
Documentation
Tools
Product Bulletins
Catalogs
White Papers
Training
Blogs
Warranties
Data Sheets