Indoor/Outdoor Digital Electricity™ Copper Cable, 2 Twisted Pair 18 AWG (7x26) Stranded Tinned Copper, PVC insulation, Unshielded, PVC Jacket, CL4, CMG
Specifications
Specifications
Product Overview
| Suitable Applications | Digital Electricity™, Fault Managed Power Systems (FMPS), remote powering, wet locations, in-conduit |
|---|
Physical Characteristics (Overall)
Conductor
| AWG | Stranding | Material | No. of Pairs |
|---|
| 18 | 7x26 | TC - Tinned Copper | 2 |
| Conductor Count | 4 |
|---|
| Total Number of Pairs | 2 |
|---|
Insulation
| Material | Nominal Wall Thickness |
|---|
| PVC - Polyvinyl Chloride | 0.017 in |
Color Chart
| Number | Color |
|---|
| 1 | Black & Red |
| 2 | Black & White |
Outer Jacket
| Material | Nominal Diameter | Nominal Wall Thickness |
|---|
| PVC - Polyvinyl Chloride | 0.352 in | 0.032 in |
Electrical Characteristics
Conductor DCR
| Nominal Conductor DCR |
|---|
| 6.4 Ohm/1000ft |
Capacitance
| Nom. Capacitance Conductor to Conductor |
|---|
| 22 pF/ft |
Current
| Max. Recommended Current [A] |
|---|
| 6.4 Amps per Conductor at 25ºC (35°C Temperature Rise) |
Voltage
| UL Voltage Rating |
|---|
| 450 V RMS |
Temperature Range
| UL Temp Rating | 105°C |
|---|
| Operating Temperature Range | -30°C To +105°C |
|---|
Mechanical Characteristics
| Bulk Cable Weight | 48 lbs/1000ft |
|---|
| Max. Pull Tension | 90 lbs |
|---|
| Min. Bend Radius/Minor Axis | 3.5 in |
|---|
Standards
| NEC Articles | Article 725, Article 800 |
|---|
| NEC/(UL) Compliance | CL4-FMP (2.5A), CL3, CMG |
|---|
| CEC/C(UL) Compliance | CMG |
|---|
| UL AWM Style Compliance | AWM 2464 |
|---|
Applicable Environmental and Other Programs
| EU Directive 2000/53/EC (ELV) | Yes |
|---|
| EU Directive 2003/11/EC (BFR) | Yes |
|---|
| EU Directive 2011/65/EU (RoHS 2) | Yes |
|---|
| EU Directive 2012/19/EU (WEEE) | Yes |
|---|
| EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
|---|
| EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
|---|
| EU CE Mark | Yes |
|---|
| EU REACH SVHC Compliance (yyyy-mm-dd) | 2019-05-13 |
|---|
Suitability
| Suitability - Indoor | Yes |
|---|
| Suitability - Outdoor | Yes |
|---|
| Suitability - Sunlight Resistance | Yes |
|---|
Flammability, LS0H, Toxicity Testing
| CSA/C(UL) Flammability | FT4 |
|---|
| UL Flammability | UL 1685 FT4 Loading |
|---|
| IEEE Flammability | 1202 |
|---|
History
| Update and Revision | Revision Number: 0.129 Revision Date: 04-24-2023 |
|---|
Documentation
Tools
Product Bulletins
Catalogs
White Papers
Training
Blogs
Warranties
Data Sheets