FX Indoor/Outdoor OM3 Distribution Tight Buffer 72 Fibers OFCP Aluminum Interlocked Armor Sub-Units(12F) Black Jacket
Specifications
Specifications
Product Overview
| Product Category | Fiber Distribution Cable |
|---|
| Suitable Applications | Premise Backbone |
|---|
| Fiber Type | OM3 |
|---|
Fiber Specifications
| Fiber Core Diameter | 50/125 µm |
|---|
| Buffer Material | PVC - Polyvinyl Chloride |
|---|
| Fiber Count | 72 |
|---|
| Buffer Diameter | 900 µm |
|---|
| Fiber Color Coding | TIA-598-D |
|---|
Cable Construction
| Number of Active Subunits | 6 |
|---|
| Fibers Per Subunit | 12 |
|---|
| Subunit Diameter | 0.220 in (5.6 mm) |
|---|
| Subunit Color | Aqua |
|---|
| Subunit Strength Members | Waterblocking aramid yarns |
|---|
| Central Strength Member | Upjacketed GRP |
|---|
| Core Wrap | Waterblocking and nomex tape |
|---|
| Cable Core Waterblocking | Waterblock Tape |
|---|
Inner Jacket Specifications
| Material | PVC - Polyvinyl Chloride |
|---|
| Nom. Diameter | 0.756 in (19.2 mm) |
|---|
| Color | Black |
|---|
| Number of Ripcords | 1 |
|---|
Armor Specifications
| Armor Type and Material | AIA - Aluminum Interlock Armor |
|---|
Outer Jacket Specifications
| Jacket Material | PVC - Polyvinyl Chloride |
|---|
| Nom. Diameter | 1.110 in (28.2 mm) |
|---|
| Color | Black |
|---|
Optical Characteristics
| Wavelength | 850 nm | 1300 nm |
|---|
| Max. Attenuation | 3.0 dB/km | 1.0 dB/km |
| 1 Gigabit Ethernet Performance | 1000 m | 550 m |
| 10 Gigabit Ethernet Performance | 300 m | -- |
| Min. Effective Modal Bandwidth (EMB) | 2000 MHz.km | -- |
| Min. Overfilled Launch (OFL) Bandwidth | 1500 MHz.km | 500 MHz.km |
Mechanical Characteristics
| Min. Bend Radius During Installation | 20x Cable OD |
|---|
| Min. Bend Radius During Operation | 10x Cable OD |
|---|
| Max. Tensile Strength During Installation | 2670 N (600 lbf) |
|---|
| Max. Tensile Strength During Operation | 800 N (180 lbf) |
|---|
| Crush Resistance | 440 N/cm |
|---|
| Bulk Cable Weight | 384 lbs/kft (571 kg/km) |
|---|
Temperature Range
| Installation Temperature Range | 0°C to +60°C |
|---|
| Operating Temperature Range | -40°C to +70°C |
|---|
| Storage Temperature Range | -40°C to +70°C |
|---|
Standards and Compliance
| Environmental Suitability | Indoor/Outdoor, Sunlight Resistance, Burial |
|---|
| Sustainability | CA Prop 65, Product Lens™, Environmental Product Declaration (EPD) Available |
|---|
| Flammability / Reaction to Fire | OFCP, FT6 |
|---|
| ICEA Compliance | S-104-696 |
|---|
| European Directive Compliance | EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE), REACH: 2020-01-16 |
|---|
History
| Update and Revision | Revision Number: 0.87 Revision Date: 11-09-2022 |
|---|
Documentation
Catalogs
Flyers
Videos
White Papers
Training
Data Sheets