FX MPO TRUNK, OS2, MPO-12(MALE TO MALE), TYPE-B, xxx M (LENGTH IN METERS)PO (144 FIBERS), 10 M, OFNP, MINI-DISTRIBUTION (2.0MM SUB-UNITS), FAN-OUT: 1.0M x IN-LINE, YELLOW JACKET
Specifications
Specifications
Product Overview
| Suitable Applications | Data Center, LAN, Equipment Room, Telecommunication room, Workstation Area |
|---|
Fiber Specifications
| Fiber Type | OS2 |
|---|
| Fiber Core Diameter | 8.2/125 µm |
|---|
| Fiber Count | 144 |
|---|
| Fiber Color Coding | TIA-598-D |
|---|
Physical Specifications
Connectors
| Description | Type | Housing Material | Housing Color | Boot Material | Boot Color |
|---|
| Connector A (Inside End) | MPO-12 Male | Plastic | Green | Rubber | Black |
| Connector B (Outside End) | MPO-12 Male | Plastic | Green | Rubber | Black |
Fan-out (Legs)
| Description | Transition | Length (m) | Diameter | Geometry |
|---|
| Connector A (Inside End) | LPM | 1.0 m | 2.0 mm | In-Line |
| Connector B (Outside End) | LPM | 1.0 m | 2.0 mm | In-Line |
Assembly Cable
| Cable Nominal OD | Jacket Color |
|---|
| 9.9 mm | Yellow |
Measurement
| Overall Assembly Length | Packaging |
|---|
| 10 m (32.8 ft) | Individually packaged in a plastic spool |
Overall Length Tolerances
| Range | Tolerance |
|---|
| 0 to 2 meters | +0.2 / -0 meter |
| 2.1 to 5 meters | +0.3 / -0 meter |
| 5.1 to 40 meters | +0.4 / -0 meter |
| over 40.1 meters | |
Armor Specifications
| Armor Type and Material | No Armor |
|---|
Optical Characteristics
| Polarity Identification | Type-B |
|---|
Fiber Connector Performance
| Description | Connector Type | Max. Insertion Loss | Min. Return Loss |
|---|
| Connector A (Inside End) | MPO-12 Male | 0.50 dB | 60 dB |
| Connector B (Outside End) | MPO-12 Male | 0.50 dB | 60 dB |
Mechanical Characteristics
| Pulling Eye Type | FX Pulling Eye |
|---|
| Pulling Eye Location | Outside End |
|---|
| Pulling Eye Tension | 100 lbs |
|---|
| Min. Bend Radius During Installation | 15x Cable OD |
|---|
| Min. Bend Radius During Operation | 10x Cable OD |
|---|
Temperature Range
| Operating Temperature Range | -10C to +60C |
|---|
| Storage Temperature Range | -10C to +60C |
|---|
Standards and Compliance
| Environmental Suitability | Indoor |
|---|
| Flammability / Reaction to Fire | OFNP |
|---|
| UL Rating | Plenum |
|---|
| TIA/EIA Compliance | TIA/EIA 568.3 |
|---|
| European Directive Compliance | EU Directive 2011/65/EU (RoHS 2) |
|---|
| MII Order #39 (China RoHS) | EUP 50 |
|---|
| Other Standard Compliance(s) | ACMA |
|---|
Product Notes
| Related Parts | DCX system, FX UHD Patch Panels, ECX Patch Panels, FX Patch cords, FX MPO Trunks, FX Multi-fiber Trunks |
|---|
History
| Update and Revision | Revision Number: 0.8 Revision Date: 04-08-2022 |
|---|
Documentation
Videos
Product Bulletins
Catalogs
Warranties
Data Sheets