Belden

GAAGD24 - Outdoor (ADSS) OFC MLT: ARAMID + PE with 6 Tubes of Ø1.9mm 24f MM OM3.

(No reviews yet) Write a Review
SKU:
GAAGD24
Shipping:
Calculated at Checkout
$0.00

Description

Outdoor dry core (ADSS) optical fiber Multi Loose Tube cable with aramid yarns as strength member and polyethylene outer jacket. Product feature: This cable has all dielectric and self-supporting properties. Existing out of 6 tubes with a diameter of 1.9mm with 24 fibers (4t x 6f) MM OM3.

Specifications

Specifications

Product Overview

Environmental SpaceOutdoor
Suitable ApplicationsAll dielectric self-supporting cable (ADSS) for Outdoor use. Particularly suitable for installation between poles with a max span of 150m. Initial sag at 20°C: 1% of span.

Construction

Fiber Cable Construction

Fiber TypeFiber CountSubunit Color
OM324TIA coding (Gxxxxxx.T): Blue, Orange, Green, Brown
Fiber Color CodingTIA coding (Gxxxxxx.T): Blue, Orange, Green, Brown, Gray, White
Central Strength MemberGRP
Cable Core Water TightYes
Cable Core WaterblockingWaterblocking Aramid Yarns + Tape
Bulk Cable Weight72 kg/km

SubUnit Specifications

Number of Active Subunits4
Number of Subunit Positions6
Fibers Per Subunit6

Jacket Specifications

Number of JacketsSingle Jacket
Type of ArmorNon-Armored

Outer Jacket Specifications

Outer Jacket

MaterialColorNominal DiameterRipcord
PE - PolyethyleneBlack10.3 mmYes

Optical Characteristics

Max. Attenuation at 1300 nm0.9 dB/km
Max. Attenuation at 850 nm2.9 dB/km

Mechanical Characteristics

Mechanical Tests

DescriptionTested StandardRequirement/ValueAccording to Family Specification
Cable Min. Bend Radius Installation (Short Term)IEC 60794-1-21-E6206 mmIEC 60794-3-10
Cable Min. Bend Radius Operation (Long Term)IEC 60794-1-21-E11206 mmIEC 60794-3-10
Cable Max. Tensile Strength Installation (Short Term)IEC 60794-1-21-E12550 N (573 lbf)IEC 60794-3-10
Cable Max. Tensile Strength Operation (Long Term)IEC 60794-1-21-E1850 N (191 lbf)IEC 60794-3-10
Cable Max. Crush Resistance Installation (Short Term)IEC 60794-1-21-E315 kN/mIEC 60794-3-10
Cable Max. Crush Resistance Operation (Long Term)IEC 60794-1-21-E37.5 kN/mIEC 60794-3-10

Temperature Range

Operating Temperature Range-30 °C to +70 °C
Installation Temperature Range-5 °C to +50 °C
Storage Temperature Range-30 °C to +70 °C

Standards

UL Rating/Flame TestNon-UL Rated
REACHCompliant
ISO/IEC ComplianceIEC 60794
UV/ Sunlight ProtectionYes

History

Update and RevisionRevision Number: 0.58 Revision Date: 01-19-2023
View AllClose

Additional Information

Variant_Options:
Item #|Color|Put-Up Type|Length|EAN
Variant_Options GAAGD24.002100:
GAAGD24.002100|Black|Reel|2,100 m|8719605154590
View AllClose