Belden

GAN31LU-A0U-604 - GAN DIN Standard Single-Ended Cordset: Form A, 4-pin (3+1PE; PE across cable outlet), grey translucent body, without circuitry, 230 V AC/DC, 10 A; PUR grey cable, 0.75 mm²

(No reviews yet) Write a Review
SKU:
GAN31LU-A0U-604
Shipping:
Calculated at Checkout
$0.00

Description

GAN DIN Standard Single-Ended Cordset: Form A, 4-pin (3+1PE; PE across cable outlet), grey translucent body, without circuitry, 230 V AC/DC, 10 A; PUR grey cable, 0.75 mm²

Specifications

Specifications

Face View

Pin 1Pin 2Pin 3PE
brownblueblackgreen-yellow
Product FamilyValve Connectors
Product Sub FamilyGAN
Connector TypeCordset, single ended
Type of Contact / GenderFemale
Connector DesignAngled
Number of Pins3+PE (PE across cable outlet)
CodingA
ShieldingUnshielded
Attachment TypeCentral Screw
Rated Impulse Voltage4.0 kV
Operating Voltage230 V AC/DC
Rated Current*10 A
Contact Resistance≤ 10 mOhm
Insulation Resistance˃ 10^9 Ohm
Mating Cycles≤ 50
Ambient Temperature (Operation)*-25 °C - +85 °C (With additional 934-887-001 gasket : -40 °C - +105 °C)
Protection Degree / IP Rating**IP65, IP67 (IP69K: without additional gasket; max. +80 °C)
Design StandardDIN EN 175301-803-A, ISO 4400
Pollution Degree3 acc. to DIN EN 60664-1 (VDE 0110-1)
Clearance / Creepage DistanceDIN EN 60664-1 (2008/01); VDE 0110-1
Overvoltage CategoryIII acc. to DIN EN 60664-1 (VDE 0110-1)

Materials

Contact Base MaterialCuZn
Contact PlatingCu/Sn
Contact Bearer MaterialPA GF
Contact Bearer Colorblack
Flammability Class (Contact Bearer)UL 94 V-0
Molded Body MaterialTPE
Molded Body ColorGrey translucent
Flammability Class (Molded Body)UL 94 HB
Attachment MaterialSteel, Philips combi slot
Gasket MaterialMolded Integrated Gasket

Circuitry

Protection CircuitryNo Circuitry
Fastening Torque (Attachment)(50-60) Ncm

Cable Data

Cable Number604
Conductor Size0.75 mm²
Number of Wires4
Minimal Bending Radius (Fixed Inst)˃ 4 x D
Minimal Bending Radius (Flexible Inst)˃ 7.5 x D
Conductor materialCu
Cable Jacket MaterialPUR
Cable Jacket Colorgrey RAL 7001
Cable Diameter Dø 6.50 ± 0.20 mm
Wire Insulation MaterialPP
Ambient Temperature (Fixed Installation)- 40 °C - + 90 °C (UL: + 80 °C)
Ambient Temperature (Flex Installation)- 20 °C - + 90 °C (UL: + 80 °C)
UL Cable TypeAWM: 21198
Flammability Class (Cable Jacket)IEC 60332-1, DIN VDE 0472 Teil 804 test method B, UL/CSA FT2
Cable CharacteristicsExclusion of dangerous materials acc. : 2000/53/EG, 2011/65/EU, 2003/11/EG, 1907/2006/EG, Restistant against acids, alkalis and solvents, UV-and ozone resistant

Approvals

VDEyes

Safety & Environmental Compliance

RoHS Compliantyes

Resistances

Halogenfreeyes
Oil ResistanceVDE 0250 and 0472

Notes

Note DeratingNotice derating
Protection Degree / IP Rating Note** only if mounted and locked in combination with Hirschmann / Lumberg Automation connector.
NoteDo not connect or disconnect under load.
View AllClose

Additional Information

Variant_Options:
Item #|Item Description|Cable Length|Replacement For
Variant_Options 9519:
9519|GAN31LU-A0U-6042000|20 m|
Variant_Options 934889078:
934889078|GAN31LU-A0U-6040200-1UC|2 m|ID: 934562008 Name: GAN-DAEE7A-FT0200C1-XC607-AD
Variant_Options 934889079:
934889079|GAN31LU-A0U-6040500-1UC|5 m|ID: 934562009 Name: GAN-DAEE7A-FT0500C1-XC607-AC
Variant_Options 7947:
7947|GAN31LU-A0U-6041000-1UB|10 m|
View AllClose