Belden

GAN3ZLU-P2M-259 - GAN DIN Standard Single-Ended Cordset: Form A, 4-pin (3+1PE; PE at cable outlet), grey translucent body, with red-green LEDs for pressure switch, 24 V AC/DC, 6 A; PUR orange cable, 0.50 mm²

(No reviews yet) Write a Review
SKU:
GAN3ZLU-P2M-259
Shipping:
Calculated at Checkout
$0.00

Description

GAN DIN Standard Single-Ended Cordset: Form A, 4-pin (3+1PE; PE at cable outlet), grey translucent body, with red-green LEDs for pressure switch, 24 V AC/DC, 6 A; PUR orange cable, 0.50 mm²

Specifications

Specifications

Face View

Pin 1Pin 2Pin 3Pin 4PE
brownwhiteblackbluegreen-yellow
Product FamilyValve Connectors
Product Sub FamilyGAN
Connector TypeCordset, single ended
Type of Contact / GenderFemale
Connector DesignAngled
Number of Pins3+PE (PE at cable outlet)
CodingA
ShieldingUnshielded
Attachment TypeCentral Screw
Rated Impulse Voltage4.0 kV (PCBA 2.0 kV)
Operating Voltage24 V AC/DC
Rated Current*6 A
Contact Resistance≤ 10 mOhm
Insulation Resistance˃ 10^9 Ohm
Mating Cycles≤ 50
Ambient Temperature (Operation)*-25 °C - +85 °C (With additional 934-887-001 gasket : -40 °C - +105 °C)
Protection Degree / IP Rating**IP65, IP67 (IP69K: without additional gasket; max. +80 °C)
Design StandardDIN EN 175301-803-A, ISO 4400
Pollution Degree3 acc. to DIN EN 60664-1 (VDE 0110-1)
Clearance / Creepage DistanceDIN EN 60664-1 (2008/01); VDE 0110-1
Overvoltage CategoryIII acc. to DIN EN 60664-1 (VDE 0110-1)

Materials

Contact Base MaterialCuZn
Contact PlatingCu/Sn
Contact Bearer MaterialPA GF
Contact Bearer Colorblack
Flammability Class (Contact Bearer)UL 94 V-0
Molded Body MaterialTPE
Molded Body ColorGrey translucent
Flammability Class (Molded Body)UL 94 HB
Attachment MaterialSteel, Philips combi slot
Gasket MaterialMolded Integrated Gasket

Circuitry

Protection CircuitryDual red-green LEDs (pressure switch)
Function IndicatorDual red-green LEDs (pressure switch)
Fastening Torque (Attachment)(50-60) Ncm

Cable Data

Cable Number259
Conductor Size0.5 mm²
Number of Wires5
Minimal Bending Radius (Fixed Inst)˃ 5 x D
Minimal Bending Radius (Flexible Inst)˃ 10 x D
Cycles (Bending)˃ 5 M
Cycles (Torsion)˃ 5 M @ ± 360 °/1 m
Conductor materialCu
Cable Jacket MaterialPUR
Cable Jacket Colororange matt similarly RAL 2003
Cable Diameter Dø 5.5 ± 0.2 mm
Wire Insulation MaterialPP
Insulated Wire Diameterø 1.50 ± 0.05 mm
Overall Shield (Cable)yes
Ambient Temperature (Fixed Installation)- 50 °C - + 90 °C (UL: +80 °C)
Ambient Temperature (Flex Installation)- 50 °C - + 90 °C (UL: +80 °C)
Ambient Temperature (Drag Chain Inst)- 25 °C - + 60 °C
UL Cable TypeAWM: 20549
Flammability Class (Cable Jacket)DIN EN 60332-2-2, VDE 0482-332-2-2, IEC 60332-2-2, CSA FT-2
Cable Characteristicsgood microbes and hydrolysis resistance, mainly plasticizer diffusion free, good chemical and oil resistance, Exclusion of PVC and Silicone, free of lacquer wetting disturbing substances

Approvals

VDEyes

Safety & Environmental Compliance

RoHS Compliantyes

Resistances

Halogenfreeyes
Oil ResistanceDIN VDE 0472-803

Notes

Note DeratingNotice derating
Protection Degree / IP Rating Note** only if mounted and locked in combination with Hirschmann / Lumberg Automation connector.
NoteDo not connect or disconnect under load.
View AllClose

Additional Information

Variant_Options:
Item #|Item Description|Cable Length
Variant_Options 934889068:
934889068|GAN3ZLU-P2M-2590500-1UC|5 m
Variant_Options 934889069:
934889069|GAN3ZLU-P2M-2591000-1UB|10 m
View AllClose