Belden

GDAD812 - Outdoor Loose Tube 12 Fibers G652D/G657A1-OS2

(No reviews yet) Write a Review
SKU:
GDAD812
Shipping:
Calculated at Checkout
$0.00

Description

Outdoor Filled Core Multi Loose Tube Optical Cable 12 x 9/125-G652D/G657A1-OS2 A-DF(ZN)2Y

Specifications

Specifications

Product Overview

Environmental SpaceOutdoor
Suitable ApplicationsFor outdoor and indoor use in structured (data) wiring systems such as industrial backbone, campus backbone, building backbone (riser) and/or horizontal cabling. For outdoor and indoor use in networks for industrial, telecom, cable TV and/or broadcast. Easy to install in ducts, tunnels and/or tubes.

Construction

Fiber Cable Construction

Fiber TypeFiber Grade acc. ITU-TFiber CountSubunit Color
OS2G652D & G657A112TIA coding (Gxxxxxx.T): Blue
Fiber Color CodingTIA coding (Gxxxxxx.T): Blue, Orange, Green, Brown, Gray, White, Red, Black, Yellow, Violet, Pink, Aqua
Central Strength MemberGRP
Cable Core Water TightYes
Cable Core WaterblockingWaterblocking Aramid Yarns
Bulk Cable Weight108 kg/km

SubUnit Specifications

Number of Active Subunits1
Number of Subunit Positions6
Fibers Per Subunit12

Jacket Specifications

Number of JacketsSingle Jacket
Type of ArmorNon-Armored

Outer Jacket Specifications

Outer Jacket

MaterialColorNominal DiameterRipcord
PE - PolyethyleneBlack12.0 mmYes

Optical Characteristics

Fiber Core Diameter9 µm
Max. Attenuation at 1310 nm0.40 dB/km
Max. Attenuation at 1550 nm0.24 dB/km

Mechanical Characteristics

Mechanical Tests

DescriptionTested StandardRequirement/ValueAccording to Family Specification
Cable Min. Bend Radius Installation (Short Term)IEC 60794-1-21-E6240 mmIEC 60794-3-10
Cable Min. Bend Radius Operation (Long Term)IEC 60794-1-21-E11240 mmIEC 60794-3-10
Cable Max. Tensile Strength Installation (Short Term)IEC 60794-1-21-E12650 N (596 lbf)IEC 60794-3-10
Cable Max. Tensile Strength Operation (Long Term)IEC 60794-1-21-E1850 N (191 lbf)IEC 60794-3-10
Cable Max. Crush Resistance Installation (Short Term)IEC 60794-1-21-E315 kN/mIEC 60794-3-10
Cable Max. Crush Resistance Operation (Long Term)IEC 60794-1-21-E37.5 kN/mIEC 60794-3-10

Temperature Range

Operating Temperature Range-30 °C to +70 °C
Installation Temperature Range-5 °C to +50 °C
Storage Temperature Range-30 °C to +70 °C

Standards

UL Rating/Flame TestNon-UL Rated
REACHCompliant
ISO/IEC ComplianceIEC 60794
UV/ Sunlight ProtectionYes

History

Update and RevisionRevision Number: 0.16 Revision Date: 11-09-2022
View AllClose