Indoor bare fiber mini optical fiber distribution cable with Low Smoke Zero Halogen outer jacket. 4 fibers MM OM2. CPR Euroclass Cca.
Specifications
Specifications
Product Overview
| Environmental Space | Indoor - Euroclass Cca |
|---|
| Suitable Applications | For indoor use in structured (premises) wiring systems: building backbone (riser) and/or horizontal cabling (Fibre To The Desk). Support all computer network applications such as FDDI, Gigabit Ethernet and ATM. Easy to install in ducts and tunnels. |
|---|
Construction
Fiber Cable Construction
| Fiber Type | Fiber Count |
|---|
| OM2 | 4 |
| Fiber Color Coding | TIA coding (Gxxxxxx.T): Blue, Orange, Green, Brown |
|---|
| Cable Core Waterblocking | Waterblocking Aramid Yarns |
|---|
| Bulk Cable Weight | 8 kg/km |
|---|
Outer Jacket Specifications
Outer Jacket
| Material | Nominal Diameter | Ripcord |
|---|
| LSZH - Low Smoke Zero Halogen (Flame Retardant) | 3.0 mm | No |
| Table Notes | Standard color: Orange. Available colors: Orange, Yellow, Turquoise, Erika Violet, Red, Blue, Green, Brown, Violet, Pink, Grey, White, Black, Lime Green |
|---|
Optical Characteristics
| Max. Attenuation at 1300 nm | 1.0 dB/km |
|---|
| Max. Attenuation at 850 nm | 2.9 dB/km |
|---|
Mechanical Characteristics
Mechanical Tests
| Description | Tested Standard | Requirement/Value | According to Family Specification |
|---|
| Cable Min. Bend Radius Installation (Short Term) | IEC 60794-1-21-E6 | 45 mm | IEC 60794-2-20 |
| Cable Min. Bend Radius Operation (Long Term) | IEC 60794-1-21-E11 | 30 mm | IEC 60794-2-20 |
| Cable Max. Tensile Strength Installation (Short Term) | IEC 60794-1-21-E1 | 150 N (34 lbf) | IEC 60794-2-20 |
| Cable Max. Crush Resistance Installation (Short Term) | IEC 60794-1-21-E3 | | IEC 60794-2-20 |
| Cable Max. Crush Resistance Operation (Long Term) | IEC 60794-1-21-E3 | | IEC 60794-2-20 |
Temperature Range
| Operating Temperature Range | 0 °C to +70 °C |
|---|
| Installation Temperature Range | -5 °C to +50 °C |
|---|
| Storage Temperature Range | -25 °C to +70 °C |
|---|
Standards
| IEC Flammability | IEC 60332-1-2 |
|---|
| Reaction to Fire - Bundle Flame Test | IEC 60332-3-24 |
|---|
| IEC 60754-1 - Halogen Amount | Zero |
|---|
| IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity | 10 µS/mm |
|---|
| IEC 60754-2 - Halogen Acid Gas Amount - Min. pH | 4.3 |
|---|
| CPR Euroclass | Cca-s1a,d1,a1 |
|---|
| REACH | Compliant |
|---|
| ISO/IEC Compliance | IEC 60794 |
|---|
History
| Update and Revision | Revision Number: 0.11 Revision Date: 01-20-2023 |
|---|
Documentation
Brochures and Guides
All Resources
Data Sheets